Security Energiser 

PTE1000 

SECURITY ELECTRONICS 

Installation & User Manual 
 
PTE1000 Series 
Security Energisers 
 

Содержание PTE1000 Series

Страница 1: ...6 Ferrier Road Narangba Qld 4504 PO Box 408 Narangba QLD 4504 Tel 07 3888 3793 Fax 07 3888 4330 Email sales pakton com au www pakton com a u Security Energiser PTE1000 SECURITY ELECTRONICS Installatio...

Страница 2: ...nal Beeper Keypad Beeper 11 Bi Polar 11 Synchronised Groups of PTE1000 s 11 Cabling 11 Lightning protection 11 Monitor Earth 11 Noise and interference 11 Programmable options 11 Low Power mode 12 6 0...

Страница 3: ...se count 13x 30 Fence Alarm Voltage Channel 1 14x 30 Fence Alarm Voltage Channel 2 15x 30 Battery Alarm Voltage 16x 31 Relay Functions 31 Relay function details 32 Group Mode 26x 32 11 0 SECTOR SETUP...

Страница 4: ...linking via the Keypad bus 41 Group Installation notes 42 APPENDIX C PTE0313 GROUP VOLTAGE DISPLAY 43 Keypad Connections Error Bookmark not defined LCD Contrast Control Error Bookmark not defined Opt...

Страница 5: ...sets of live wires around a secure area The live wires are powered by the energiser and monitored so that if the live wires are shorted to ground or cut an alarm is sounded The energiser places a ver...

Страница 6: ...ccess to the backup battery via a panel in the front of the case 9 Full remote control via optional keypad 10 May be connected to a building alarm 11 Many digitally adjustable parameters including fen...

Страница 7: ...ry contact Change over Relay rated at 1A 30V Table 1 PTE1000 Specifications Notes x Specifications subject to change without notice x The switches on the cabinet are internally wired to the control in...

Страница 8: ...n and User Manual for PTE1000 V4 08 07 2006 10 11 PM Page 8 of 43 5 0 Description Parts of the PTE1000 Voltage Display Fence Terminals Status Lights Battery Access Cover Output terminals Return monito...

Страница 9: ...table in chapter 9 Energiser Base parts Low Voltage connections AC Power in 16Vac via a pre wired plug pack May be 220Vac in some countries On off switch Local switch for arming the energiser Keypad c...

Страница 10: ...re is no panic function Models The PTE1013 is a single channel security energiser The PTE1013 is capable of conventional or Bi polar operation In Bi polar operation the PTE1013 display both the positi...

Страница 11: ...voltage cabling fence lead out and returns should be run using suitably rated cable Double insulated electric fence underground cable is suitable High Voltage Cables should never be run within the sam...

Страница 12: ...situations where the fence is not required to be a deterrent but is still required to actively detect intrusion In Low Power mode the fence live wires operate at a much lower voltage typically 500V pe...

Страница 13: ...terminals must be tight if they are loose and spark it could cause erratic behaviour 7 Ensure that the unit is switched off at the switches or remote device if one is connected 8 Connect battery 9 Tur...

Страница 14: ...PTE101x Single Channel Energiser configured for conventional fence operation ENERGISER EARTH PTE101x Single Channel Energiser configure for bi polar fence operation Energiser Earth Conventional Fence...

Страница 15: ...050 Lightning Diverters The first example shows the Lightning Diverters fitted at the Energiser while the second shows them fitted at the fence Note in the second example the Energiser and Fence earth...

Страница 16: ...User Manual for PTE1000 V4 08 07 2006 10 11 PM Page 16 of 43 Lightning Diverters fitted at the fence PTE102x Dual Channel Energiser Fence Lightning Diverters Reference Earth Fence and Lightning Earth...

Страница 17: ...SWITCHING THE FENCE ON ARMING Enter your PIN number four digits long and push the key Make sure the red ARM light comes on The keypad will beep twice to confirm that the system is armed The fence will...

Страница 18: ...re your new PIN works by using it to arm the energiser The default PIN is 1234 STANDBY BATTERY Should there be a loss of mains power the Power light on the keypad will go out If the loss of power is p...

Страница 19: ...19 of 43 9 0 Technical information technicians section Figure 1 PTE101x Low Voltage Wiring Diagram 2A M205 Glass Fuse 2A M205 Glass Fuse 16V AC Power 12V DC Battery Control input Expansion Port Keypad...

Страница 20: ...age 20 of 43 Figure 2 PTE102x Low Voltage Wiring Diagram 2A M205 Glass Fuse 2A M205 Glass Fuse 16V AC Power 12V DC Ch1 control input Display Port Keypad Bus Channel 1 Relay Output Channel 2 Relay Outp...

Страница 21: ...general alarm functions on PTE101x units RLY3 3 Way Relay 3 PTE102x only Defaults to General alarm relay output Changes to alarm state on AC fail Flat Battery or PCB error Keypad 3 Way Supplies power...

Страница 22: ...ntually be depleted and the energiser will stop Once AC power has been restored and the battery has recovered the energiser will re arm itself automatically A tamper or a PCB fault will stop the energ...

Страница 23: ...07 2006 10 11 PM Page 23 of 43 dry contacts for IN1 and IN2 Do not use unless the control signal is coming from a voltage free contact i e a relay J7 2 As above J8 1 Links IN2 to Keypad screw termina...

Страница 24: ...er Manual for PTE1000 V4 08 07 2006 10 11 PM Page 24 of 43 Figure 3 PTE101x High Voltage Wiring Diagram Earth Negative Fence Output Positive Fence Output Monitor Earth Negative Return Channel 2 Positi...

Страница 25: ...11 PM Page 25 of 43 Figure 4 PTE102x High Voltage Wiring Diagram NOTE The order of the return terminals is different to that of the output terminals Earth Channel 1 Fence Output Channel 2 Fence Output...

Страница 26: ...ed The default Installer PIN is 012345 To exit programming mode After programming press to exit if left unattended the unit will time out and auto exit after about 5 minutes Change the installer PIN T...

Страница 27: ...larm will occur 11 Input type Allows the energiser inputs to be changed from normally open to closed 13 Missed pulse count Sets the number of pulses which may be missed bad before the alarm is activat...

Страница 28: ...n will automatically mute Power level both channels 05x The power level option allows the shocking power of the fence to be adjusted For example To change the power level to maximum enter the followin...

Страница 29: ...nputs can be driven from 0 12V or dry contacts if J6 J7 are fitted PTE101x are dry contact only This option allows the polarity to be inverted Normal Turn ON with 12V or Open contact Reverse Turn ON w...

Страница 30: ...Voltage is 3 kV Fence Alarm Voltage Channel 2 15x Sets the voltage threshold below which the fence alarm will occur for channel 2 The default Fence Alarm Voltage is 3 kV The default Fence Alarm Volta...

Страница 31: ...able below The defaults for the PTE101x are Relay 1 Fence Bi polar Relay 2 General Relay 3 N A Relay 4 daughter board Armed 1 Relay 5 daughter board0 Armed 2 The defaults for the PTE102x are Relay 1 F...

Страница 32: ...l error Latched for internal errors only Siren Fence alarm 1 OR fence alarm 2 OR Tamper will time out after the siren time out time This function is latched Strobe As per siren but does not time out w...

Страница 33: ...rthed point should be less then a few hundred volts the voltage on the earth stake with respect to any nearby earthed metal should be less then a few hundred volts 5 Record the start and end of fence...

Страница 34: ...your questions or comments to Pakton Phone 07 3888 3793 International 61 7 3888 3793 Fax 07 3888 4330 International 61 7 3888 4330 E mail sales pakton com au Mailing address PO Box 1068 BURPENGARY DC...

Страница 35: ...e avoided 5 An electric fence shall not be supplied from two different energizers or from independent fence circuits of the same energizer For any two different electric fences each supplied from a di...

Страница 36: ...es are installed near an overhead power line their height above the ground shall not exceed 2 m This height applies either side of the orthogonal projection of the outermost conductors of the power li...

Страница 37: ...r is being maintained in the physical barrier Note 2 When selecting the type of physical barrier the likely presence of young children should be a factor in considering the size of openings LOCATION O...

Страница 38: ...2006 10 11 PM Page 38 of 43 Figure 7 Typical Constructions where an Electric Security Fence is Exposed to the Public Note 2 Typical electric security fence installations are shown in Figure 9 and Figu...

Страница 39: ...e at least one dimension in each opening in the physical barrier is not greater than 130 mm greater than 1 000 mm where any opening in the physical barrier has all dimensions greater than 50 mm less t...

Страница 40: ...an electric fence should not be energized unless all authorized persons within or entering the secure area have been informed of its location Where there is a risk of persons being injured by a second...

Страница 41: ...from one unit to the keypad optional and 2 wires to every other unit in the group Do not connect the lines between PTE1000 s as this could result in some strange behaviour and possibly damage Note the...

Страница 42: ...ielded or twisted pair cable for the group keypad wiring 5 You will need to program the group mode option on each of the units before operating as a group Do this by connecting a keypad to each unit o...

Страница 43: ...Support for PTE101x or PTE102x Energisers x PTE101x in Bi polar or conventional mode x Upper and lower alarm thresholds x Zone configuration x Compatible with an LED keypad The Lite version is limited...