Provisioning
150-231-181-01, Revision 01
16
September 7, 1999
HLU-231 List 8A
Span Status Screen without Doublers
Figure 5.
Span Status Screen: No Doubler
Span Status Screen for Doubler Applications
If doublers have been added, status is also reported for these. Span Status can have up to five screens, depending
on the number of HDUs.
Figure 6.
Span Status Screen: Four Doublers (Span 5)
SPAN STATUS
TIME: 00:27:25
DATE: 08/05/99
CIRCUIT ID#:
ALARMS:
NONE
LOOPBACK: OFF
POWER LEVEL: LOW
HLU
HRU
HDSL-1
HDSL-2
HDSL-1
HDSL-2
cur/min/max
cur/min/max
cur/min/max
cur/min/max
MARGIN:
21/20/22
23/22/24
21/19/22
22/21/24 dB
PULSE ATTN:
00
00
00
00
dB
INS LOSS:
00
00
00
00
dB
24 HOUR ES:
00004
00003
00006
00007
seconds
24 HOUR UAS:
00014
00013
00000
00001
seconds
DS1 STATUS
HLU
HRU
24 HOUR ES Count:
00001
00002
24 HOUR UAS Count:
00000
00002
Frame type:
SF
SF
Code type:
AMI
AMI
AUTOUPDATE OFF
(E)xit (C)lear (A)uto(U)pdate
SPAN 5 STATUS
TIME: 12:06:04
DATE: 08/05/99
ALARMS:
NONE
LOOPBACK: OFF
POWER LEVEL: HIGH
HDU4
HRU
HDSL-1
HDSL-2
HDSL-1
HDSL-2
cur/min/max
cur/min/max
cur/min/max
cur/min/max
MARGIN:
23/23/23
23/21/23
24/20/25
24/21/24
dB
PULSE ATTN:
07
07
07
07
dB
INS LOSS:
08
08
08
08
dB
24 HOUR ES:
00010
00008
00001
00002
seconds
24 HOUR UAS:
00021
00020
00004
00002
seconds
DS1 STATUS
HLU
HRU
24 HOUR ES Count:
00000
00017
24 HOUR UAS Count:
00000
00012
Frame type:
ESF
ESF
Code type:
AMI
AMI
AUTOUPDATE OFF
(E)xit (C)lear (A)uto(U)pdate (S)pan(1)(2)(3)(4)(5)