Screen Menus and Definitions
A-22
Setup Menu Screens
From the Setup Menu you can view the PG-Flex system current system setup and change the
following configurable options: time slots assignments, channel configuration, POTS loop/ground
start setup, and ISDN channel setup. Refer to Figure A-5 for a block diagram of the Setup Menu
structure.
System Settings
From the System Settings menu you can change a PG-Flex systems parameter. Refer to Table A-3
on page 24 for the System Settings menu options.
01-SEP-97 PAIRGAIN TECHNOLOGIES INC., PG-FLEX TERMINAL 00:03:02
SYSTEM ID: PG-Flex 24 Channel System SYSTEM: 1
CURRENT STATUS: OK LOGGED IN: COT
ALARMING TERMINAL: NONE
CHREV: SPAN 1
SETUP MENU
------------------------------------------------------------------------------
A) SYSTEM SETUP
B) TIME SLOTS ASSIGNMENT
C) CHANNEL CONFIGURATION
D) POTS LOOP/GROUND START SETUP
E) ISDN CHANNEL SETUP
CTRL-X) Main Menu e(X)it
[COT] ENTER COMMAND> a
01-SEP-97 PAIRGAIN TECHNOLOGIES INC., PG-FLEX TERMINAL 03:39:52
SYSTEM ID: PG-Flex 24 Channel System SYSTEM: 1
SYSTEM SETTINGS
------------------------------------------------------------------------------
A)
SYSTEM DATE: . . . . . 01-SEP-97
B)
SYSTEM TIME: . . . . . 03:39:52
C)
SYSTEM ID: . . . . . . PG-Flex 24 Channel System
D)
SET PASSWORD . . . . .
E)
AUTO LOGOUT TIME (min.): . . 5
(DISABLED,5,30,60)
F)
METERED TONE FREQUENCY (kHz): . DISABLED
(DISABLED,12,16)
G)
RING FREQUENCY (Hz): . . 20
(20,25,30)
H)
HDSL ES ALARM THRESHOLD: . . 17
(DISABLED,17,170)
I)
HDSL MARGIN THRESHOLD: . . . 6
(0-15,0=DISABLED)
J)
ALARM ON HDSL THRESHOLD: . . ENABLED
(DISABLED,ENABLED)
K)
LOCAL LOOP LENGTH: . . . LONG
(SHORT,LONG)
L)
ALARM ON CONFIGURATION: . . ENABLED
(DISABLED,ENABLED)
M)
ALARM ON INSUFFICIENT TIMESLOT: ENABLED
(DISABLED,ENABLED)
N)
ALARM ON ISDN PM THRESHOLD:
ENABLED
(DISABLED,ENABLED)
CTRL-X) Main Menu e(X)it
[RT] ENTER CHOICE> A
Содержание PG-Flex
Страница 10: ...PG Flex System Overview 2 Figure 1 Typical PG Flex Configuration 23 Shelf shown ...
Страница 24: ...PG Flex System Overview 16 ...
Страница 44: ...Installing PG Flex System Hardware 36 Figure 16 Line Unit and Channel Unit Installation Locations ...
Страница 52: ...Installing PG Flex System Hardware 44 Figure 21 Connecting the Metallic Bypass Pair ...
Страница 62: ...Installing PG Flex System Hardware 54 ...
Страница 66: ...Terminal Management 58 Figure 28 Connecting an ASCII Terminal to a Line Unit ...
Страница 104: ...Performance Monitoring 96 ...
Страница 120: ...Troubleshooting 112 ...
Страница 158: ...Screen Menus and Definitions A 36 ...
Страница 162: ...Acronyms and Glossary Glossary 4 ...
Страница 167: ......
Страница 168: ......