Subscriber Drop Testing
107
Metallic Access Sample Menus
From the Metallic Access Menu, type a letter (
through
) and press
. The Metallic
Access selection Menu is displayed on your terminal screen:
To test a subscriber drop.
From the Metallic Access Menu, select the access required.
(Refer to Table 33, “Metallic Access Menu Options,” on page 106 for description of each option).
1
Select the card and channel for the subscriber circuit being tested. (Metallic access to the
selected circuit is provided at the test jack on the FPI-729 List 1 or FAU-728 List 2 front panel.)
2
At the prompt for the system to be tested, enter the card number followed by a comma, and then
enter the channel number. The Metallic Access Menu displays:
3
Use a VOM, Butt-in, or other test equipment to test the subscriber circuit.
A
G
Enter
29-JUN-97 PAIRGAIN TECHNOLOGIES INC., PG-FLEX TERMINAL 00:18:50
SYSTEM ID: PG-Flex 24 Channel System SYSTEM: 1
CURRENT STATUS: OK LOGGED IN: COT
ALARMING TERMINAL: NONE
CHREV: SPAN 1
METALLIC ACCESS
------------------------------------------------------------------------------
Press ESCAPE to return to previous menu
Enter Card and Channel To Be Accessed/Bypassed (CARD,CHANNEL): 2,1
29-JUN-97 PAIRGAIN TECHNOLOGIES INC., PG-FLEX TERMINAL 00:19:14
SYSTEM ID: PG-Flex 24 Channel System SYSTEM: 1
CURRENT STATUS: TEST LOGGED IN: COT
ALARMING TERMINAL: NONE
CHREV: SPAN 1
METALLIC ACCESS MENU
------------------------------------------------------------------------------
A) COT - BRIDGING (ENABLED ON CU2/CH1)
B) COT - LOOKING IN
C) COT - LOOKING OUT
D) RT - LOOKING OUT
E) RT - LOOKING IN
F) RT - BRIDGING
G) SUBSCRIBER BYPASS
R)emove access
CTRL-X) Main Menu e(X)it
[COT] ENTER COMMAND>
Содержание PG-Flex
Страница 10: ...PG Flex System Overview 2 Figure 1 Typical PG Flex Configuration 23 Shelf shown ...
Страница 24: ...PG Flex System Overview 16 ...
Страница 44: ...Installing PG Flex System Hardware 36 Figure 16 Line Unit and Channel Unit Installation Locations ...
Страница 52: ...Installing PG Flex System Hardware 44 Figure 21 Connecting the Metallic Bypass Pair ...
Страница 62: ...Installing PG Flex System Hardware 54 ...
Страница 66: ...Terminal Management 58 Figure 28 Connecting an ASCII Terminal to a Line Unit ...
Страница 104: ...Performance Monitoring 96 ...
Страница 120: ...Troubleshooting 112 ...
Страница 158: ...Screen Menus and Definitions A 36 ...
Страница 162: ...Acronyms and Glossary Glossary 4 ...
Страница 167: ......
Страница 168: ......