350-431-116-01, Revision 01
Testing
HLU-431 List 1F
January 8, 1999
13
A
LARMS
Only one alarm can be displayed at a time on the front panel display,
therefore, only the highest priority alarm is displayed if more than one alarm
exists. The following table lists the alarms in order of priority.
Table 4.
Status Menu Alarm Messages
Message
Full Name
Description
ALRM
Alarm Condition Exists
A system alarm condition is in effect.
LLOS
Local Loss of Signal
No signal at the HLU-
431
List
1F
local T1
interface.
RLOS
Remote Loss of Signal
No signal at the HRU remote T1 interface.
LOSW
Loss of Sync Word
HDSL Loop 1 or 2 has lost sync.
H1ES or
H2ES
HDSL Loop 1 or 2 Errored
Second
Loop 1 or 2 CRCs have exceeded the user
selected ES threshold.
DS1
Digital Service 1
DS1 input BPVs at the HRU have exceeded the
user selected ES threshold.
RAIS or
LAIS
Remote Alarm Indicating
Signal
Indicates an AIS pattern of all ones is being
transmitted from the remote or T1 output port.
MAL1 or
MAL2
Margin Alarm 1 or 2
The margin on HDSL Loop 1 or 2 has dropped
below the threshold (1 to 15 dB) set by the user.
CHREV
Channels Reserved
The Loop 1 and 2 HDSL pairs are reversed at the
HRU input port. Loop 1 is specified to carry the
(-) simplex dc voltage, and Loop 2 is specified to
carry the (+) simplex dc voltage.
ACO
Alarm Cut-off
A minor alarm occurred and was retired to an
ACO condition after pressing the SEL button on
the HLU front panel.