12.  TESTING

12.01

Table 2 provides a step by step test 
procedure for the HRU-612 unit.  This

procedure allows verification of the integrity of the
VHDSL channel to the HLU Line Hit as well as the
DS1 channels to the customer and the HLU DSX-1
interface.  Table 3 lists the HLU status messages
which may also be helpful when coordinating turn-up
with CO personnel.

12.02

The HLU’s 4 character front panel has many
useful diagnostic messages.  They are listed

in Table 3.

12.03

If trouble is encountered at the T1 interface, 
verify that the unit is making a positive

connection with the mounting assembly’s connector.

TABLE 3.  HLU 4 CHARACTER FRONT PANEL MESSAGES.

Message

Full Name

Description

CREM

Customer Remote Loopback

Signal from customer is looped back to customer at HLU-

611

NLOC

Network Local Loopback

DSX signal is looped back to DSX at HLU

CLOC

Customer Local Loopback

Signal from Customer is looped back to customer at HRU-

612

NREM

Network Remote Loopback

DSX signal is looped back to DSX at HRU

SMJK

Remote Smartjack Loopback

Signal from DSX is looped back at HRU by the HRU
smartjack module.

TLOS

Transmit Loss of Signal

The HRU is in a logic loopback state caused by a loss of its
T1 input from the NI, if enabled by the SAIS option.

FERR

Framing Bit Error Occurred

Framing bit error occurred at HLU T1 input

LBPV

Local Bipolar Violation

A bipolar violation has been received at the T1 input to the

HLU-611.

SIG1

Signal

The  HLU & HRU  transceivers are trying to establish
contact with each other.

ACQ1

Acquisition

The HLU & HRU multiplexers are trying to establish
synchronization over each loop.

HES

HDSL CRC Error

At least 1 CRC error on the VHDSL Loop in the last second.

ARM

HiGain-2 System ARMED

Armed to respond to  Intelligent Repeater Loop Codes

ACO

Alarm CutOff

A  MNRALM has occurred, and been retired to an ACO
condition, by depressing  the SEL button on the HLU front
panel.

SELF TEST

Self Test

The HLU is in a self test mode.  This occurs every power

ON/OFF cycle.

ALRM

Alarm Condition Exists

A minor alarm condition is in effect.

Table continued on next page

Содержание HiGain-2 HRU-612

Страница 1: ...IONS 2 3 SPECIFICATIONS 3 4 CERTIFICATION 3 5 WARRANTY 4 6 TECHNICAL ASSISTANCE 4 B FUNCTIONAL DESCRIPTION 7 FUNCTIONAL OPERATION 4 8 FRONT PANEL 6 9 OPTIONS 7 10 LOOPBACKS 9 C INSTALLATION AND TEST 1...

Страница 2: ...smart jack loopback Conforms to TR TSY 000312 Provisioning switches for CPE current RCV LBO and XMT LOS initiated loopback or AIS Front panel jacks for test access RS 232 front panel terminal access f...

Страница 3: ...50 Celsius 5 to 95 non condensing Mounting Single width 400 type mechanics slot Dimensions 5 6 H x 1 4 W x 5 6 D 4 CERTIFICATION 4 01 FCC Compliance The HRU 612 List 2 has been tested and found to co...

Страница 4: ...Technical Assistance is available 24 hours a day 7 days a week by contacting PairGain s Customer Service Engineering group at one of the following numbers Telephone 800 638 0031 714 832 9922 Fax 714 8...

Страница 5: ...the screen displays The port is configured as DCE with 8 data bits 1 stop bit and no parity Striking the SPACE bar several times invokes autobaud from 1200 to 9600 baud Note that if the RS 232 port in...

Страница 6: ...B NET GREEN LED indicating the HRU is in a loopback state in which the signal from the NETwork is being looped back to the NETwork CI YELLOW LED indicating the HRU is in a loopback state in which the...

Страница 7: ...611 100 for more details The HRU also has three user options set by switches located at the back of the unit as shown in Figure 4 Each switch has two settings as follows refer to the block diagram in...

Страница 8: ...en the HRU does not function as the NID but is connected to an external NID It allows the external NID to set the appropriate NI level 15 Configures the T1 RCV LEVEL to 15 dB This sets the T1 output s...

Страница 9: ...t jack loopback state It remains in this state until a loopdown command is detected or the default time out period if enabled expires 10 04 When the HRU is in its AIS ENA smart jack metallic loop back...

Страница 10: ...ed or unframed The loop down command for both is the standard 3 in 5 five second pattern C INSTALLATION AND TEST 11 INSTALLATION 11 01 Upon receipt of the equipment visually inspect it for signs of da...

Страница 11: ...e C O 7 To verify that the proper ports are use for the VHDSL DS1 pairs use an ohm meter to verify that the VHDSL HRU 612 port has a 180 k T to R resistive signature in contrast to the DS1 ports which...

Страница 12: ...ustomer at HRU 612 NREM Network Remote Loopback DSX signal is looped back to DSX at HRU SMJK Remote Smartjack Loopback Signal from DSX is looped back at HRU by the HRU smartjack module TLOS Transmit L...

Страница 13: ...ng System Settings review mode defined above FRM Frame SF ESF UNFR NONE Defines the type of frame pattern being received from the DSX 1 Displayed during System Settings mode defined above CODE Line Co...

Страница 14: ...tiated by 2 in 5 in band loopback code or out of band ESF data link code See Figure 5 NREM Network Remote Loopback Loopback at HRU remote towards network initiated from C O network by intelligent line...

Страница 15: ...Hour ES Errored Seconds The number of 1 second intervals that contained at least 1 CRC error This value is a running total of the last 24 Hours VHDSL 24 Hour UAS Unavailable Seconds The number of sec...

Страница 16: ...Section 150 612 102 Revision 03 Page 16 Figure 7 HRU 612 Maintenance Terminal Main Menu Figure 8 HRU 612 View Span Status Display...

Страница 17: ...Section 150 612 102 Revision 03 Page 17 Figure 9 HRU 612 System Settings Menu Figure 10 HRU 612 Set Clock Menu...

Страница 18: ...Section 150 612 102 Revision 03 Page 18 Figure 11 HRU 612 View Performance Data Display Figure 12 HRU 612 View Performance History Display...

Страница 19: ...2 102 Revision 03 Page 19 Figure 13 HRU 612 View Alarm History Display Copyright 1996 PairGain Technologies Inc PairGain is a registered trademark CopperOptics and HiGain are trademarks of PairGain Te...

Отзывы: