Maintenance
150-431-115-01, Revision 01
28
September 22, 1998
HLU-431 List 1E
Figure 14.
NLOC Loopback Mode in the Maintenance Terminal Main Menu
Disable Loopbacks
The Disable Loopbacks option allows you to disable (cancel) any of the loopbacks listed in the screen. To disable
loopbacks, press
in the Loopback Menu. The following prompt appears:
PLEASE WAIT................
A series of dots moves from left to right indicating that the command has been issued. When this process
completes, the system returns to the Maintenance Terminal Main Menu in which the Loopback Mode will display
as None.
P
ERFORMANCE
D
ATA
S
CREENS
The Performance Data screens show the Errored (ES) and Unavailable Seconds (UAS) for both HDSL loops and
each T1 input at 15-minute intervals over a 4-hour time interval. Earlier and later data, in 4-hour time periods on
different span screens, can be accessed by pressing
(Previous) or
(Next) respectively. All Performance Data
counters can be set to zero by pressing
(Clear) from the HLU-431 Span Status screen shown below.
Since the HLU-431 is considered the master module, this clears
all performance data screens at
both the HLU-431 and the HRU. The RS-232 interface at the HRU does not allow the counters to
be cleared.
HI-GAIN HLU-431 MAINTENANCE TERMINAL MAIN MENU (ver V5.1L-5)
CIRCUIT ID#:
A. VIEW SPAN STATUS
B. SET CLOCK
C. SYSTEM SETTINGS
D. LOOPBACK MODE: NLOC
E. VIEW PERFORMANCE DATA
F. VIEW PERFORMANCE HISTORY
G. VIEW ALARM HISTORY
H. ENTER CIRCUIT ID #