Installation and Test
363-704-121-01, Revision 01
6
July 30, 1999
FLC-704 List 2A
INSTALLATION AND TEST
U
NPACKING
THE
FLC-704
Upon receipt of the equipment, proceed as follows:
•
Unpack each container and visually inspect the contents for signs of damage. If the equipment has been
damaged in transit, immediately report the extent of damage to the transportation company and to PairGain.
Order replacement equipment if necessary.
•
Check the contents versus the packing list to ensure complete and accurate shipment. If the shipment is short
or irregular, contact PairGain as described in the
.
If you must store the equipment for a prolonged period, store the equipment in its original container.
T
URN
-U
P
AND
T
ESTING
Install COT Channel Units
1
Insert each FLC-704 into the COT shelf.
All LEDs on the Channel Unit will turn on for approximately
1
/
2
second, then scan from top to bottom, then
flash all on, then off.
2
After the system has powered up, established HDSL synchronized communications, and no calls are in
progress, verify that the Channel Unit front panel indicators ACTIVE 1 through ACTIVE 8 and FAULT
LEDs are all off.
Test Subscriber Circuits. Test each subscriber circuit by placing and receiving calls; ACTIVE 1 through 8 LEDs
track call progress.
T
ROUBLESHOOTING
Table 2, “FLC-704 Troubleshooting,” on page7
provides troubleshooting procedures based on indications
displayed by the front panel indicators of FLC-704.