![PairGain 150-1260-24 Скачать руководство пользователя страница 26](http://html1.mh-extra.com/html/pairgain/150-1260-24/150-1260-24_manual_747320026.webp)
Section 150-441-124
June 12, 1997
Revision 01
Page 22
PairGain Engineering - Plant Series
HiGain HLU-D41
15. Maintenance Terminal Main Menu
15.1
There are eight menus available for system administration from the Maintenance Terminal Main
menu. Table 12 describes the function of each menu selection.
Table 12. Maintenance Terminal Menus
Menu
Function
See
View Span Status
Provides access to submenus that allow you to monitor the S-HDSL line
between the HLU-D41 and the HRU-512.
Section 16
Set Clock
Allows you to set both the time and the date parameters at the
HLU-D41, and to update the same settings at the HRU-512.
Section 17
System Settings
Allows you to set all user options.
Section 18
Loopback Mode
Provides access to submenus that allow you to issue and disable
loopbacks from both the network and customer side.
Section 19
View Performance
Data
Provides access to submenus that allow you to view the Errored
Seconds (ES) and Unavailable Seconds (UAS) between the HLU-D41
and the HRU-512 in 15-minute intervals over a four-hour time period.
Section 20
View Performance
History
Provides access to submenus that allow you to view the ES and UAS
between the HLU-D41 and the HRU-512 in 15-minute intervals over a
seven-day period.
Section 21
View Alarm History
Provides access to submenus that allow you to view alarm conditions
between the HLU-D41 and the HRU-512.
Section 22
Enter Circuit ID #
Allows you to enter a unique circuit ID (up to 24 characters)
Section 23
15.2
To display the Maintenance Terminal Main menu:
1
Press the <spacebar> several times to initiate the RS-232 connection.
The Maintenance Terminal Main menu appears: