background image

7

MA45-25E

Drawing no: M10879-2

2017-06-07 ASA

Installation elvärmare 3-fas

1.

6.

7.

10.

2.

3

4.

3.

5.

9.

>

5

0

0

Ø50

>200

8.

Ø50

>200

1.

Electric heater Aqua compact

ENGLISH

Product description

For swimming pools up to 100m

3

.

The heater comes with an adjustable thermostat with a temperature range 0-45° C, overheating protection with a maximum 
refractive temperature of 60° C and a flow switch that breaks voltage when the water flow is less than 90 l/min. 

 

Casing is made of reinforced thermoplastic, short (3, 6, 9 kW) or long (12, 15, 18 kW).
The heater is available in two different versions: Incoloy 825 or with a titanium power cartridge. Titan is used in aggressive 

 

water, salt water or in pools with chlorine machine/salt chlorinator.
Connections are made of PVC for internal attachments to PVC pipes Ø50 mm.

Technical data 

Dimensions

Minimum flow 

90 l/min

Voltaget: 

230V 1-phase (3–6kW)
230V 3-phase (3–18kW)
400V 3-phase (3–18kW)

Max. pressure: 

2,5 bar

Max. temperature: 

45°C

Effect

Item no. Incoloy

Item no. Titan

  3kW

141600

141600T

  6kW

141601

141601T

  9kW

141602

141602T 

12kW

141603

141603T

15kW

141604

141604T

18kW 

141605

141605T

General installation instruction

The heater should be installed at least 200 mm below normal water level in the pool, see example.
Connection must be made with PVC tube Ø50mm (int. Ø42mm) with at least 200 mm straight length before and after the heater. 
Mount the heater so that it is always full of water.
If the heater is placed against combustible material, place a fireproof disc or a similar object between the heater and the wall. 
The disc should cover 10 cm outside the heater external wall. The heater must not be covered.
Install the heater in such a way that it can be drained of all water.
The heater must be installed on the return line to the pool after the filter. Do not install a shut-off valve between the heater and 
the pool. If a valve is required, install a check valve.
Chlorine, acid or the like dosing should be done AFTER the heater to avoid corrosion.

1.  Skimmer

2.  Inlet

3.  Light
4.  JetSwim
5.  Main drain
6.  Pump
7.  Filter

8.  Electric heater
9.  Check valve

10. Drain

Отзывы: