Warranty

A manufacturer’s warranty is included with your Pact Sense device for one year from the
purchase date. To be covered under the warranty, all you need is your receipt. If your device was
a gift, just gently twist the gift-giver’s arm for proof of purchase (a bank or credit card statement is
fine if they can’t find a receipt).

 

This warranty excludes:

Damage caused by accident, abuse, mishandling, or water

Devices repaired by an unauthorized service representative

Devices not used in accordance with Pact's usage, storage and care instructions

Failure to provide a dated proof of purchase and serial number of your Pact Sense

To have your Pact Sense repaired or replaced under the warranty, please contact

[email protected]

to begin your claim. Please do not try and repair the unit yourself, as this

will void the warranty. Unless otherwise instructed by Pact, the device must be returned in either
its original packaging or packaging affording an equal degree of shipping protection to the facility
specified by Pact.

 

Pact may ask the purchaser to provide proof of purchase details and respond to questions
designed to help with identifying potential issues. If Pact determines that the problem with the
device is not due to a manufacturing defect, the device is not properly returned to Pact, or
otherwise does not qualify for warranty repair, then the purchaser will be responsible for all costs
incurred by Pact necessary to return the device.

Maintenance

Cleaning the Measurement Probe

Extend probe by triple tapping button with device on

Use a alcohol wipe to clean probe

Single tap to exit cleaning mode

Manufacturer Servicing

Pact Sense has no user-serviceable parts. Repairs, battery change, calibration and testing can be
performed only by Impact Biosystems. Contact

[email protected]

for servicing requests.

Impact Biosystems, Inc.

5 Colebrook St. Boston, MA 02127

www.thepact.com

[email protected]

7

Содержание Sense

Страница 1: ...User Manual Pact Sense Muscle Scanner PLEASE READ PRIOR TO USE v1 0 Sept 2022 Impact Biosystems Inc 5 Colebrook St Boston MA 02127 www thepact com support thepact com 1...

Страница 2: ...tart 3 Operation 5 Warranty 7 Maintenance 7 Storage 8 Cleaning 8 Safety 9 Technical Specifications 10 Device Firmware 13 Troubleshooting 14 Change Log 16 Impact Biosystems Inc 5 Colebrook St Boston MA...

Страница 3: ...he light s color will indicate the charge level Solid green indicates 100 charged Setup the Pact Mobile App Scan the QR Code to install the app Follow in app instructions to create your account https...

Страница 4: ...e documentation One package contains One Pact Sense One USB A to USB C Charging Cable One 7 5W Power Adapter One Hard Shell Carry Case If the content of the package does not conform to the list of doc...

Страница 5: ...LED will glow white when it is connected 4 Follow the app instructions to prepare your scanning session 5 Lightly press the Pact Sense into the target tissue Follow app guidance for pressure and place...

Страница 6: ...dio Signals Beeps are used to communicate throughout the scanning process One beep the scanner will beep at the end of each muscle group in the scanning flow to indicate that it s time to move on to t...

Страница 7: ...by Pact the device must be returned in either its original packaging or packaging affording an equal degree of shipping protection to the facility specified by Pact Pact may ask the purchaser to prov...

Страница 8: ...d with a dry soft cloth Avoid getting water and other liquids inside the device Alcohol wipes can be used to disinfect surfaces that come in contact with skin such as the measurement tip and moving ri...

Страница 9: ...from heated surfaces 7 Do not use outdoors 8 Do not drop the device 9 Do not insert any object into any opening 10 Do not reach for an appliance that has fallen into water Unplug immediately 11 Do not...

Страница 10: ...e Measurable parameters Stiffness N m Amount of force produced by the skin as a result of the measurement probe depressing into the tissue Stiffness Slope N m2 Relationship between stiffness and depth...

Страница 11: ...0 cycles Single Charge operation period Min 1 000 measurements Power management Automatic shut down in 10 minutes with Bluetooth connectivity Automatic shut down in 5 minutes without Bluetooth connect...

Страница 12: ...duct Height 110 mm Diameter 70 mm Weight 340 g Packaging Height 75 mm Width 100 mm Depth 180 mm Weight with device and charger 550 g Impact Biosystems Inc 5 Colebrook St Boston MA 02127 www thepact co...

Страница 13: ...pen and keep your Pact Sense in close proximity to the mobile device 8 The firmware update is complete when the app displays the popup Firmware updated Press Ok to return to the app home screen See Tr...

Страница 14: ...wall outlet If no LED indication occurs try removing and reconnecting the USB C cable Triple tap button to attempt to enter cleaning test mode If LED indication still does not turn on the device may b...

Страница 15: ...rmware update before you can use the device again Retry the update by going to Settings Update Firmware SAVE THESE INSTRUCTIONS This device complies with part 15 of FCC Rules Operation is subject to t...

Страница 16: ...Change Log Version Change v1 0 Initial Release Impact Biosystems Inc 5 Colebrook St Boston MA 02127 www thepact com support thepact com 16...

Отзывы: