background image

                                                Packet Power

 

Multi-Circuit Monitor BGS16 User Manual V2.0

  

 

 

 

© 2021 Packet Power, LLC 

 

Page 4 of 27

 

Regulatory Information  

 

 

 

 

 

 
Monitoring Units 

 
This product has been tested to the following requirements: 

 

CONFORMS TO UL/IEC STD 61010-01, 3rd ed.IEC 61010-2-030 ed. 1.0, EN 61010-1:2010, CSA C22.2 NO. 61010-1 

 

IEC 61010-2-032 - Edition 2 - Issue Date 2002/09/01, EN 61010-1:2001, 

IEC 61010-1, 3rd Edition 

 

 

Council Directive 1999/05/EC - European Union (EU) Radio & Telecommunications Terminal Equipment Directive 
(R&TTE) ETSI EN 300 220-2 v2.4.1, ETSI EN 300 328 V1.7.1 and ETSI EN 301 489-1 and 301 489-3, Issued:2002/08/01 
V1.4.1, EN61326-1, EN6100-3-2, EN6100-3-3, EN301 489-17, AS/NZS CISPR 11 

 

IC RSS-210 Issue 8 Annex 8, RSS-GEN Issue 3 

 

FCC CFR 47.15(c), 15.247(a) 

 
 

BGS16 Assembly 

 

This product has been tested to the following requirements: UL508A Industrial Control Panel 

 

 
 

Class B Device Statement:

 

 

Section 15.105(a) of the FCC Rules: This equipment has been tested and found to comply with the limits for a Class B digital device, 
pursuant to part 15 of the FCC Rules.  These limits are designed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment.  This equipment generates, uses, and can radiate radio frequency energy and, if 
not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.   
 
Section 15.19 of the FCC Rules: This device complies with part 15 of the FCC Rules. Operation is subject to the following two 
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including 
interference that may cause undesired operation. 

Содержание BGS16

Страница 1: ...wer Multi Circuit Monitor BGS16 User Manual V2 0 BGS16 Multi Circuit Monitoring System Installation Operations and Maintenance Manual Version 2 0 Packet Power 2716 Summer St NE Minneapolis MN 55413 1...

Страница 2: ...ice Current transformers shall provide two means of isolation from hazardous voltages When selecting a current transformer the voltage and measurement category of the circuit to be measured must be co...

Страница 3: ...ailure to observe the information following this symbol may result in injury or death CAUTION This system and the area it is installed in may contain life threatening voltages Qualified personnel must...

Страница 4: ...ssembly This product has been tested to the following requirements UL508A Industrial Control Panel Class B Device Statement Section 15 105 a of the FCC Rules This equipment has been tested and found t...

Страница 5: ...a supplement to information provided in the support section of Packet Power s web site www packetpower com support The BGS16 must be used in conjunction with a Packet Power Ethernet Gateway Detailed...

Страница 6: ...Current Transformers 7 Communication 8 Components 9 SECTION 3 INSTALLATION 10 Installation Overview 10 Mounting 10 Voltage Connection 12 CT Interconnect Cable and Board 15 CT Leads 15 CTs 16 SECTION 4...

Страница 7: ...t you are monitoring matches the type indicated on the label of the BGS16 The BGS16 cannot be used on 480V equipment if access to N is not present nor on 600 347V circuits The BGS16 is powered from th...

Страница 8: ...Gateways can be added for capacity or redundancy The BGS16 must be able to establish a wireless connection either directly to a Gateway or to another Packet Power wireless device Data can be accessed...

Страница 9: ...itor BGS16 User Manual V2 0 2021 Packet Power LLC Page 9 of 27 Components The BGS16 consists of a NEMA 1 monitoring enclosure one CT interconnect board with loose CT leads or wire harnesses for attach...

Страница 10: ...es not need to be configured prior to use 1 Mount the BGS16 to wall or device using mounting tabs provided 2 Run the voltage lead s to the voltage source and connect them to L1 L2 L3 N and earth 3 Mou...

Страница 11: ...r wire exits in the back bottom and on each side of the enclosure allowing it to be mounted in a variety of positions relative to the equipment being monitored Wire exit location Description Bottom 1...

Страница 12: ...ge disconnect near the BGS16 that is used to avoid placing strain on the connection to the terminal block during shipping and installation 5x20 mm 5A inline fuses are included on L1 L2 and L3 unless o...

Страница 13: ...Packet Power Multi Circuit Monitor BGS16 User Manual V2 0 2021 Packet Power LLC Page 13 of 27 Voltage wire connections by service type...

Страница 14: ...Packet Power Multi Circuit Monitor BGS16 User Manual V2 0 2021 Packet Power LLC Page 14 of 27...

Страница 15: ...re to orient the CT Interconnect Board so the black connector header faces away from the circuits or panel Attach Interconnect Cable to Interconnect Board Attach the connector at the end of the CT Int...

Страница 16: ...ch CT lead will have a label standard labels are CT1 CT2 CT3 etc CTs The BGS16 supports 6 to 16 split core or Rogowski coil CTs of varied amperage and size SPLIT CORE CTs Split core CT Specifications...

Страница 17: ...d into place Connect CT tails to CT leads CT leads coming from the CT Interconnect Board will typically be labeled CT1 CT2 CT3 etc unless otherwise specified Connect the CT tail to the corresponding C...

Страница 18: ...ion the coil on the conductor such that the arrow on the connector faces toward the load and away from the source 4 Close the Rogowski coil and ensure the closing unit has clicked into place Connect R...

Страница 19: ...nd associates each CT to its component meter See Appendix for sample This documentation is required in order to access readings using protocols such as SNMP or Modbus Customers using Packet Power s EM...

Страница 20: ...es Follow the wire harness on the side of the terminal block that feeds into the BGS16 to locate the inline fuse holders Open each fuse holder and inspect for blown fuses Replace with 5x20mm glass 5A...

Страница 21: ...en entered on the master gateway If V readings are present but A and W are missing o If only one reading is missing follow the process listed in the Maintenance section of this document to remove the...

Страница 22: ...ENANCE Equipment Parts List Contact Packet Power support if you encounter issues related to any parts or before attempting any repairs Of these items the following can be replaced in the field by qual...

Страница 23: ...LIT CORE CT 1 Disconnect power to the BGS16 if possible If it is not possible to disconnect power always treat CT leads as though they carry line voltages Work on live panels must only be performed by...

Страница 24: ...uick disconnect attached to the cable 3 Open the Rogowski coil by pinching the closing unit on the side of the connector and remove from the conductor 4 Position the new coil on the conductor such tha...

Страница 25: ...LLC Page 25 of 27 Dismantling The BGS16 contains components that may fall under local electronics disposal guidelines Please adhere to local requirements No lead is used in the BGS16 Emergency Measure...

Страница 26: ...based on customer provided information e g panel name etc E The radio zone that the meters in the BGS16 are set to F The location at which the wires will exit the BGS16 enclosure G The type of voltag...

Страница 27: ...Packet Power Multi Circuit Monitor BGS16 User Manual V2 0 2021 Packet Power LLC Page 27 of 27 C D E F G H I A B...