LMX SERIES™ OPERATION MANUAL
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 115 of 463
6.5.2
Scope Measurements
Scope measurements allow all voltage and current phases to be captured and displayed in
the time domain. From one to four cycles of the fundamental frequency can be displayed.
Display modes include all voltages, all currents, both voltage and current or individual phase
selected voltage and current. Use the “Scope” soft key from the Measurement screen to
select Scope measurements.
Note that voltage scope captures can be set for Line to Neutral voltage or Line to Line
Voltage when in three phase mode. To select the desired mode, use the Select Channel soft
key.