AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 221 of 485
8.4.2
Frequency Measurement Commands
Query Format
MEASure:FREQuency?
Description
Returns the fundamental frequency.
Returned Data Format
<nr2>
Query Example
MEAS:FREQ?
50.0000
8.4.3
Current Measurement Commands
Query Format
MEASure:CURRent[:ACDC]#?
Description
Returns the measured RMS current for the selected phase #. If no
phase number is specified, returns the reading for all phases.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:ACDC1?
21.1587
Query Format
MEASure:CURRent:PEAK#[:ABSolute]?
Description
Returns the measured peak current value for the selected phase #. If
no phase number is specified, returns the reading for all phases.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:PEAK?
45.5845, 47.3213, 48,2234
Query Format
MEASure:CURRent:PEAK#[:ABSolute]:HOLD?
Description
Returns the measured peak hold current value for the selected phase
#. If no phase number is specified, returns the reading for all phases.
This reading accumulates the highest recorded absolute peak current
until reset using the MEASure:CURRent:PEAK#:RESet command.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:PEAK:HOLD?
58.5845, 57.3213, 58,2234
Query Format
MEASure:CURRent:PEAK#:MINimum?
Description
Returns the lowest measured peak current value for the selected
phase #. If no phase number is specified, returns the reading for all
phases.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:PEAK:MIN?
1.0001, 0.8451, 0.4871