6.4.3
Changing Shuttle Programming Resolution
Once entering EDIT mode on any programmable field – by double clicking the shuttle knob –
the parameter value can be slewed by turning the knob. The setting resolution can be
changed as needed. If a large value change is needed, a lower resolution will result in a
faster change, e.g. changing voltage 10V per click or 1V per click. For a very small change, a
0.1V or 0.01V change per click may be more appropriate.
The selected resolution is reflected by the blinking character when in edit slew mode. To
change the position and thus resolution, use the keypad numeric keys. The lowest number
keys will select the smallest increment/decrement setting. The higher number keys will
select a larger increment/decrement setting.
The table bellows maps the keypad keys to the resolution setting.
Key Pad Key #
Position
Resolution
1 or 2
0.01
3
0.1
4
1
5
10
6, 7, 8 or 9
100
7, 8, 9
1000
Table 6-3: Changing Programming Resolution