![Pacific Power Source 105LMX Скачать руководство пользователя страница 187](http://html.mh-extra.com/html/pacific-power-source/105lmx/105lmx_operation-manual_746366187.webp)
LMX SERIES™ OPERATION MANUAL
SECTION 7: Auxiliary I/O
Error! Reference source not found.
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 187 of 463
7.6.2
Phase Sync Output
SYNC
IN/OUT
The phase sync output signal can be programmed to generate an output pulse at each zero
crossing of the phase A voltage. This indicates the 0° phase angle output on Phase A.
The mode can be set from the front panel or by using the following SCPI commands:
The following specifications apply to the external trigger output:
Output Voltage @ 0.4 mA Logic Low Vout < 0.4 V
Log High Vout > 4.6 V
Max. Current
± 10 mA
Output Impedance
100
Ω
Pulse Width
100 us ± 10 us
Figure 7-8: Phase A Zero Phase Sync Output Pulse