8
SERVICING - LEAD ACID BATTERIES (NON-HYDROLINK® MODELS)
WARNING:
Batteries emit hydrogen and oxygen gas
-
Keep sparks and open flame away. Do not smoke near the machine
-
Charge batteries in a well-ventilated area with the battery compartment open
WARNING:
Do not wear jewelry when working near moving or electrical components
CAUTION:
Always wear protective clothing, gloves and goggles when handling and charging batteries
REQUIRED EQUIPMENT
Eye protection
Acid resistant gloves
Distilled water
Baking soda (neutralizes acid spills)
SAFETY
Never:
Add acid to a battery
Smoke near batteries
Charge a frozen battery
Leave an acid spill unattended
Store batteries unless they are fully charged
Charge a battery when the temperature is above 122°F (50°C)
Charge a flooded battery without securing vent caps on the cells
Place objects on top of batteries, which can cause a short circuit
Always:
Neutralize acid spills with baking soda and water
Use insulated tools and check connections for proper torque
WATERING
If contact with electrolyte (sulfuric acid) occurs, flush with large amounts of water
Use only distilled water (tap water can contain contaminants that will damage the battery)
Remove the caps and place them upside down to check electrolyte levels
For discharged or partially charged batteries, add just enough water to cover the plates
Fully charge the batteries
Add distilled water to a level of 1/8” below the vent well
CLEANING AND INSPECTION
Fluid on the top of a battery may mean it is being over-watered or overcharged
Check cleanliness and keep terminals and connectors free of corrosion
Clean with a solution of 1 cup baking soda to 1 gallon of water
Do not allow cleaning solution to get inside the battery
Rinse with water and dry with a clean cloth
Keep the area around batteries clean and dry
Properly secure all vent caps
Check battery cables and connections. Replace any damaged cables and tighten any loose connections
Add distilled water to a level
of 1/8”below the vent well
Remove the caps and place
them upside down to check
Содержание S-28
Страница 56: ...BATTERYSHIELD OPTIONAL WIRING DIAGRAM 56 RETURN TO TABLE OF CONTENTS...
Страница 57: ...CHEMICAL INJECTION OPTIONAL WIRING DIAGRAM 57 RETURN TO TABLE OF CONTENTS...
Страница 58: ...58 MAINTENANCE LOG DATE MAINTENANCE PERFORMED RETURN TO TABLE OF CONTENTS...
Страница 60: ...60 http www pacificfloorcare com RETURN TO TABLE OF CONTENTS...