S-20 ORBITAL WIRING DIAGRAM
*if equipped
*if equipped
TROUBLESHOOTING TIPS
•
If the scrub head is not working properly when lowered, be
aware that BatteryShield® intentionally disables the scrub
head when the batteries need water. Refer to the
BatteryShield® section of this manual.
•
For machines equipped with BatteryShield® refer to the
BatteryShield® wiring diagram and instructions prior to
proceeding.
•
If a yellow LED is flashing on the battery charger, verify
continuity between the charger and the battery pack.
•
A circuit breaker is designed to prevent overloading a
component. If a circuit breaker continues to trip, verify the
system is not being overloaded or that a wire is not chaffed
creating a short‐circuit.