background image

2

Contents

Caution ...................................................................................................... 3

Maintenance .............................................................................................. 4

Installation................................................................................................. 5

Clearances ................................................................................................. 6

Venting....................................................................................................... 7

Gas Supply ................................................................................................ 7

Blocked Vent Shut-off System ................................................................. 8

Draft Inspection ........................................................................................ 8

Surround Assembly .................................................................................. 9

Log Set ..................................................................................................... 10

Glowing Embers ..................................................................................... 12

Levelling Legs ......................................................................................... 12

Glass Frame Installation ........................................................................ 12

Louver Installation ................................................................................. 13

Optional Radiant Overlay ..................................................................... 13

Lighting Instructions .............................................................................. 14

First Fire .................................................................................................. 15

Operation................................................................................................. 15

Primary Air Adjustment ........................................................................ 15

Burner Removal...................................................................................... 16

Propane Conversion ............................................................................... 17

Optional Blower ...................................................................................... 18

Replacement Parts .................................................................................. 20

Burner Replacement Parts .................................................................... 22

Label ........................................................................................................ 23

23

FOR USE WITH/

NATURAL GAS/

LP-GAS/

EN CASE D’EMPLOI AVEC:

DU GAZ NATUREL DU GAZ LP

Minimum supply pressure / Pression minimum d’alimentation:

5.0 in/wc / 5.0 po/c.e.

12.5 in/wc / 12.5 po/c.e.

(For the purpose of input adjustment/dans le but de regler l’alimenation)

(1.25 kPa)

(3.11 kPa)

Manifold pressure / Pression de la tuyauterie:

3.8 in/wc / 3.8 po/c.e.

11.0 in/wc / 11.0 po/c.e.

(.95 kPa)

(2.74 kPa)

Orifice Size /  Diametre de l’injectuer:

# 45

(2.08 mm)

# 55

(1.32 mm)

Input BTU/hr (kW)  /  Puissance à l'entrée BTU/h (kW) :

Max.: 21,000

(6.2)

Max.: 21,000

(6.2)

Min.: 10,500

(3.1)

Min.:

10,500

(3.1)

Optional components:  Blower Kit (MINB.BLOW) / Éléments facultatifs:  Ventilateur (MINB.BLOW)

Blower electrical rating:  115v, 60hz, 0.5 A / Normes electriques du ventilateur:  115v, 60hz, 0.5 A

This appliance equipped for altitudes 0-4500 ft. (0-1370 m) / Cet unité est concu pour des altitudes variant entre 0- 4500

pieds (0-1370 m). Also certified for installation in a bedroom or a bedsitting room / Aussi certifié pour installation dans

une chambre à coucher ou une salle de séjour.
This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion

and ventilation air. Par mesure de securite, cet appareil doit etre installe de facon a assurer un approvisionnement

suffisant d’air de combustion et de ventilation. This vented gas fireplace is not for use with air filters. Ne pas utiliser de

filtre à air avec foyer au gaz à évacuation.

WARNING:  Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.

Refer to the owner’s information manual provided with this appliance. For assistance or additional information, consult a

qualified installer, service agency or the gas supplier.
This appliance must be installed in accordance with local codes, if any; if not, follow the current CAN/CGA-B149

(Canada) or ANSI Z223.1 (USA). Cet appareil diot etre installe conformement aux exigences des codes locaux. S’il

n’existe aucun code local, se conformer a la norme CAN/CGA-B149 en vigueur.
Left and Right side are determined when facing the front of the appliance.

Les cotes droit et gauche se determinent en se mettant devant l’appareil et en lui faisant face.
INSTALL IN SOLID FUEL BURNING  FIREPLACE / N'INSTALLER QUE DANS UN FOYER NON COMBUSTIBLE

MINIMUM CLEARANCES TO COMBUSTIBLES /

Fireplace Insert /

DEGAGEMENT DES MATIERES INFLAMMABLES

Encart de la cheminée

Adjacent Sidewall / Mur du côté adjacent :

9.5 in. / 9.5 po.

(241 mm)

Ceiling / Plafond :

38 in. / 38 po.

(965 mm)

Mantel to Appliance / Du manteau al’appareil :

9 in. / 9 po.

(229 mm)

Max. Mantel Extension / Extension max. dmanteau :

12 in. / 12 po.

(305 mm)

Facing Side and Top / :

1 in. / 1 po.

(25 mm)

040701

5050.7203

1-FFGA

PACIFIC ENERGY

FIREPLACE PRODUCTS LTD.

PO Box 1060, Duncan,

British Columbia, V9L 3Y2

MODEL / MODELE:

  

FAIRFIELD - INSERT

   

SERIES / SERIE:

  

 A

ANSI Z21.88-1999b / CAN 2.33-M99  Vented Gas Fireplace

Heaters,  CAN/CGA-2.17 -M91 Gas-Fired Appliances For Use

At High Altitudes

REPORT NO.

476-1936-00

L18582

VENTED GAS FIREPLACE HEATER - NOT FOR

USE WITH SOLID FUEL

FOYER AU GAZ À ÉVACUATION - NE PAS

UTILISER AVEC DU COMBUSTIBLE SOLIDE.

CERTIFIED FOR CANADA AND U.S.A. / CERTIFIÉ POUR CANADA ET U.S.A.

WH

WH

DO NOT REMOVE OR

COVER THIS LABEL

MADE IN CANADA  /  FABRIQUE AU CANADA

This Appliance is Equipped For Use With   /

Cet Appareil est Équipé Pour Utilise Avec :

NATURAL GAS

GAZ NATUREL

LP-GAS

LP GAZ

Label

f i r e - p a r t s . c o m

Содержание Series A

Страница 1: ...ately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed b...

Страница 2: ...t for use with air filters Ne pas utiliser de filtre air avec foyer au gaz vacuation WARNING Improper installation adjustment alteration service or maintenance can cause injury or property damage Refe...

Страница 3: ...y piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa Standard size Surrou...

Страница 4: ...water Glass Panel Warning Do not operate appliance with glass panel re moved cracked or broken Replacement of the glass panel should be done by a licensed or qualified service person Do not strike or...

Страница 5: ...Replacement Glass Panel GLAS 2078 16 Surround Side Left Met Black standard size FFGA 29771MB Surround Side Left Porc Blue standard size FFGA 2977BE Surround Side Left Porc Black standard size FFGA 29...

Страница 6: ...e and Top to appliance surround 1 in 25 mm Combustible Mantel 38 in 965 mm 9 1 2 in 241 mm 9 in 229 mm 12 in 305 mm MANTEL CEILING ADJACENT WALL Top or Side Facing 19 Fig 39 Fig 38 Fig 37 4 Run the po...

Страница 7: ...n The gas control is equipped with a capture screw type pressure test port therefore it is not necessary to provide an 1 8 inch N P T plugged tapping pressure port for checking gas pressure immediatel...

Страница 8: ...as cooled 2 Note log positions and carefully remove them if in stalled 3 Remove glowing embers and save them for reuse if installed 4 Remove the screws located on the rear corners of the burner fasten...

Страница 9: ...ews just inside the casing near the top and bottom Pushsurroundbackuntilsnugandevenwithfront face of insert Fasten in place 8 Push the entire appliance back until the surround is in contact with the f...

Страница 10: ...isadjustmentispresetatthefactory for the best flame appearance for most installations How ever adjustment is available to compensate for varying field conditions such as gas BTU content or altitude th...

Страница 11: ...ll not stay lit after several tries turn the gas control knob to Off and call your service technician or gas supplier 9 Turn gas control knob counter clockwise to On position 10 Turn HI LO burner cont...

Страница 12: ...rame assembly and hook over the frame tabs Ensure that the tabs on the top of the unit engage the corresponding slots in the glass frame 2 Swing the bottom into position and latch in place with the ov...

Отзывы: