INSTALLATION 

AND OPERATING 

INSTRUCTIONS

SAFETY NOTICE

If this Fireplace is not properly installed, 
a house fire may result.  For your safety, 
follow the installation instructions. 
Contact local building or fire officials 
about restrictions and installation 
inspection requirements in your area.

IMPORTANT:

THESE INSTRUCTIONS ARE TO 

REMAIN WITH THE HOMEOWNER.

MODEL:  

FP16 LE, 

FP16 AR LE

SERIAL #

Meets the U.S. Environmental Protection 
Agency's 2020 Particulate Emission Standards 
for Cord Wood

Visit www.pacificenergy.net for the most recent version of this manual

TESTED and LISTED to;
 CAN/ULC S610 AND UL127

Содержание FP16 LE

Страница 1: ...ocal building or fire officials about restrictions and installation inspection requirements in your area IMPORTANT THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER MODEL FP16 LE FP16 AR LE SERIAL M...

Страница 2: ...oor Glass Gaskets 11 Blowers 11 Baffle 11 Baffle Removal 12 Secondary Air Box Cleaning 12 Blower Replacement 13 Fireplace Installation 14 Locating your Fireplace 14 Mobile Home Installation notes 14 C...

Страница 3: ...E DESSERVANT UN AUTRE APPAREIL NE PAS OBSTRUER PAS LES OUVERTURES DEVANT LE FOYER NI RESTREINDRE L ALIMENTATION D AIR N CESSAIRE POUR LE FONC TIONNEMENT NORMAL DU FOYER TEL QUE SP CIFI DANS LES INSTRU...

Страница 4: ...without ample air the smoke cannot burn Smoke free clean burning requires small fuel loads two or three logs at a time or 1 4 to 1 2 of fuel load and leaving the air inlet relatively wide open especi...

Страница 5: ...d cracks before starting another fire Also check combustibles around the chimney and the roof We strongly recommend that your chimney be inspected by professionals who are certified by one of the foll...

Страница 6: ...r heat sources How to Test Your Wood Add a large piece of wood to the stove when it has a good large bed of coals It is dry if it is burning on more than one side within one minute It is damp if it tu...

Страница 7: ...ly ignited and engulfed in flame 3 After the kindling is burnt down 50 add 2 3 small split pieces or small logs 1 25mm diameter Crack the door open approximately 1 25mm 2 100mm until the start up wood...

Страница 8: ...s towards the front of the heater Add a couple of dry split logs on top of the embers close door 2 Adjust the Air Control to high and in just a few minutes logs should begin burning 3 After wood has c...

Страница 9: ...y Firebrick Visual for cracking Door Gasket sagging placement damage Monthly Brick rail tabs and brick rails Air riser tube in the back of the firebox Back side of airwash chamber Baffle locking pin B...

Страница 10: ...replace any necessary components to the chimney system Maintain a distance of 48 1 2m to all combustible materials in the room See also Ember Protector on page 23 for the Floor Protection dimensions...

Страница 11: ...WARNING DO NOT SLAM LOADING DOOR OR OTHERWISE IMPACT GLASS WHEN CLOSING DOOR MAKE SURE THAT NO LOGS PROTRUDE TO IMPACT THE GLASS IF THE GLASS GETS CRACKED OR BROKEN IT MUST BE REPLACED BEFORE USING TH...

Страница 12: ...ffle If the insulation is damaged during removal it should be replaced The baffle should only be removed after the chimney is being cleaned Secondary Air Box Cleaning The Secondary Air Box Cleaning sh...

Страница 13: ...he blower mounting bracket up and pull towards you to disengae the slots from the bolts If replacing the right side blower disconnect the two wires leading to the thermal switch on the bracket before...

Страница 14: ...actor in the chimney performance Therefore the chimney out let position is important when locating the fireplace We recommend whenever possible that the chimney should Penetrate the highest part of th...

Страница 15: ...h of floor protection from side of door opening 8 200mm Minimum depth of non combustible ember protector from the front of the fireplace 18 455mm Minimum chimney height minimum total chimney height fr...

Страница 16: ...ions The open volume inside the chase is required for heat management Do Not build a recess shelves or cup boards in the area above this fire place Do not build anything inside this Minimum chase area...

Страница 17: ...ttom stud 2 and then attach the top stud 2 to the center supports 3 Installing the unit into the chase Push the Fireplace into place Casing must be flush with the framing in the front and secure if re...

Страница 18: ...the chimney manufacturer s installation requirements Consult your chimney supplier for installation advice 1 After locating the desired location and framing in the fireplace use a plumb bob to line u...

Страница 19: ...the first 20 6 1m in length 1 NOTE Install the vertical chimney section s then the first elbow and turn it in the required direction 2 Install the necessary chimney lengths to achieve the required off...

Страница 20: ...learances around the chimney for its entire length must be to code as per the National Building Code or NFPA 211 The masonry chimney can only be used for this fireplace and no other appliances Make su...

Страница 21: ...h minimum rodent screen and staple nail in place Provide water protection as required by building code Attach 4 102mm venting not supplied between the units adapter and the inlet vent A typical outsid...

Страница 22: ...support base Figure 16 Connect the wiring as shown in the wiring diagram Figure 17 to the wires located in the junction box See Blower Replacement on page 13 All electrical connections should be perf...

Страница 23: ...ion must be protected with a 2 51mm deep safety metal strip equal to the width of the unit One half of the metal strip must be under the fireplace front and the other half must extend onto the floor a...

Страница 24: ...rer s recommendations The cement board must cover from the floor to a height of 6ft 1 83m from the bottom of the fireplace or 43 1 2 1 105m from the top facing stop and 44 1 12m wide centered on the u...

Страница 25: ...e has a built in facing edge stop DO NOT PLACE ANY CEMENT BOARD OR FINISHING MATERIALS INSIDE THIS EDGE Failure to comply will result in improper installation of panels overheating of the fireplace an...

Страница 26: ...d in the area highlighted below Extending from the outer edge of the door out 12 292mm Under the door down to the floor Above the Heat Exchanger s Air Deflector up to a minimum of Figure 23 FP16 LE Ma...

Страница 27: ...hearth must be completly constructed of non combustible materials Minimum width of floor protection from side of door opening 8 200mm Minimum depth of non combustible ember protector from the front o...

Страница 28: ...position install firebricks as follows 1 Install the rear firebricks two on each side of the baffle tube 2 Place the vetical side bricks then tuck the horizontal side brick under the retaining tabs an...

Страница 29: ...wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Air control is set too high Set control lower 2 Not enough...

Страница 30: ...g Door NEO 1 6 80001929 12 Door Handle Assembly NEO 80001754 13 Door Assembly Met Black NEO 1 6 80000233 14 Brick Rail Kit 80000235 15 Rear Brick Rail 80001723 16 Replacement Baffle Kit NE16 BAFKIT 17...

Страница 31: ...r Assembly Hinge Side 80002452 6 Switch 120 10 air mount 80001814 8 Door Gasket 80000670 9 Glass Retainer 80002356 10 Replacement Glass c w Tape 80000220 12 Door Handle Assembly NEO 80001754 14 Brick...

Страница 32: ...ion or translation without prior written permission is prohibited except as allowed under the copyright laws For technical support please contact your retailer Web site www pacificenergy net 2975 Alle...

Отзывы: