PEC017
5/3/2018
Page
70
of
105
PS27
Min
Default
Max
Units
1400
N/A
PS29
RPM
*Minimum engine speed limit is 1400 RPM to ensure proper control system stability
when PGS is active
*Maximum engine speed limit is 1650 RPM to ensure the proper balance between
fuel economy shifting and providing power while accelerating
PS28
Min
Default
Max
Units
>PS26
N/A
<PS30
GEAR #
*Never program PGS to be active in top gear
PS29
Min
Default
Max
Units
PS27
N/A
1800
RPM
*The minimum RPM after a shift in any gear should not fall below 1100 RPM
PS30
Min
Default
Max
Units
>PS30
N/A
*
GEAR #
*Never program PGS to be active in top gear
ON/OFF Requirements
Progressive Shift
ON
OFF
ENTER SALES CODE
(Progressive Shift ON)
No Sales Code
(Progressive Shift OFF)
GDP
ON
OFF
ENTER SALES CODE
(Gear Down Protection ON)
No Sales Code
(Gear Down Protection OFF)