PEC017
5/3/2018
Page
62
of
105
N085
Page
Min
Default
Max
Units
Engine Speed Ramp-Up w/Set/Accel
(In-Cab)
10
250
1000
RPM/SEC
N087
Page
Min
Default
Max
Units
PTO Mode Preset Engine Speed (In-
Cab)
0
780
2000
RPM
* To Enable,
Engine Speed Capture or Engine Speed Preset w/ Set Switch (N110)
must be PRESET (0)
N110
Page
Min
Default
Max
Units
Engine Speed Capture or Engine
Speed Preset w/ Set Switch
PRESET
(0)
CAPTURE
(1)
CAPTURE
(1)
N/A
* Mobile PTO applications require engine speed capture (1)
Remote Control Configuration, Limits, and Set Points
N055
Page
Min
Default
Max
Units
Remote PTO Preset Engine Speed
1
0
780
2000
RPM
N056
Page
Min
Default
Max
Units
Remote PTO Preset Engine Speed
2
0
1030
2000
RPM
* Must be greater than or equal to
Remote PTO Preset Engine Speed 1 (N055)
N073
Page
Min
Default
Max
Units
Accelerator Pedal Type in PTO
Mode
TORQUE
(0)
SPEED
(1)
SPEED
(1)
N/A
N088
Page
Min
Default
Max
Units
Remote PTO in Vehicle Parked
State
OFF (0)
ON (1)
ON (1)
ON/OFF
N090
Page
Min
Default
Max
Units
Engine Speed Decrease
w/Res/Decel (Remote)
10
50
1000
RPM
Содержание MX Series