PEC 013
Page
49
of
71
12/20/13
Parameter Name
Number
Min/Max/Default/Units
Maximum rate to change PTO speed after
switch bump
To Enable, Set N109 = 1
N081
MIN = 50 (RPM/SEC)
MAX = 200 (RPM/SEC)
DEFAULT = 75
(RPM/SEC)
Rate to increase PTO speed with in-cab
Set/Accel switch held
N085
MIN = 10 (RPM/SEC)
MAX = 1000 (RPM/SEC)
DEFAULT = 350
(RPM/SEC)
Rate to decrease PTO speed with in-cab
Resume/Decel switch held
N084
MIN = 10 (RPM/SEC)
MAX = 1000 (RPM/SEC)
DEFAULT = 250
(RPM/SEC)
Minimum engine speed during PTO
operation
N106
MIN = 650 (RPM)
MAX = 2000 (RPM)
DEFAULT = 650 (RPM)
Maximum engine speed during PTO
operation
N086
MIN = IDLE (RPM)
MAX = 2000 (RPM)
DEFAULT = 2000 (RPM)
Value to increase PTO speed with
Remote Set/Accel switch bump
N092
MIN = 10 (RPM)
MAX = 1000 (RPM)
DEFAULT = 50 (RPM)
Value to decrease PTO speed with
Remote Resume/Decel switch bump
N090
MIN = 10 (RPM)
MAX = 1000 (RPM)
DEFAULT = 50 (RPM)