PEC 013
Page
48
of
71
12/20/13
Parameter Name
Number
Min/Max/Default/Units
PTO ON/OFF Interlock Remote Station
Controls With Transmission-Driven PTO
(For stationary applications)
Requirements to enable (N088 = 0)
N079 = 1
N080 = 1
N089 = 0
N088
MIN = 0 (ON)
MAX = 1 (OFF)
DEFAULT= 1 (OFF)
Limits and Set Points
Parameter Name
Number
Min/Max/Default/Units
Value to increase PTO speed with in-cab
Set/Accel switch bump
N083
MIN = 10 (RPM)
MAX = 200 (RPM)
DEFAULT = 50 (RPM)
Value to decrease PTO speed with in-cab
Resume/Decel switch bump
N082
MIN = 10 (RPM)
MAX = 200 (RPM)
DEFAULT = 50 (RPM)
Enable Pre-Programmed PTO speed set
point (N087)
In-Cab use only
Not available with mobile applications
N110
MIN = 0 (ON)
MAX = 1 (OFF)
DEFAUL T= 1 (OFF)
Pre-Programmed PTO speed set point
reached with the first in-cab Set/Accel
switch bump
To Enable, Set N110 = 0
N087
MIN = 0 (RPM)
MAX = 2000 (RPM)
DEFAULT = 780 (RPM)
Enable Maximum rate to change PTO
speed after switch bump (N081)
N109
MIN = 0 (OFF)
MAX = 1 (ON)
DEFAUL T= 0 (OFF)