background image

INSTRUCTIONS AND PARTS LIST,  SILVER-8/31/2011

Supersedes Instructions & Parts list, SILVER-11/04/2008

WARNING:

Spray materials may be harmful if inhaled or allowed

to come into contact with skin or eyes. Consult the product label

and  Material  Safety  Data  Sheet  supplied  for  the  spray  material.

Follow  all  safety  precautions. 

CAUTION:

Well  Ventilated

Area  Required  to  remove  fumes,  dust  or  overspray.

Check  compatibility  of  materials  used  with  Polyethylene

container and PVC Fluid Hose. Secure airhose and fluid

hose wrench tight for safety and to prevent leaks.

M a x i m u m   A i r   P r e s s u r e   6 0   P . S . I .

M a x i m u m   F l u i d   P r e s s u r e   4 5   P . S . I .

BUS2RS and BUS2FS

DUAL FLUID SPRAY GUNS

OPERATING INSTRUCTIONS AND REPLACEMENT PARTS

INTRODUCTION:

These Manual Spray Guns require clean dry air pressure
regulated to provide from 6 to 8 C.F.M. at 40 to 60 lbs. air
pressure  depending  on  size  and  number  of  atomizing
heads  to  be  used.  Paasche  Regulator  &  Condenser
Units are recommended for attaching to air supply line to
remove  water,  oil,  rust  or  scale  and  help  insure  quality
finish  of  coating.    They  have  no  parts  that  require
replacement and clean themselves each time the drain
valve  is  opened  to  remove  accumulation  of  filtered
contaminates.

AIR AND FLUID CONNECTIONS:

1. Air  Connection:    To  remove  any  accumulated

foreign matter blow out all hoses before using.

a.  Air  supply  to  Spray  Gun  must  be  turned  off

before attaching fittings to the Air Inlet.

b.  Attach HT-1/4 Air Hose to the Air Outlet on the

Air  Regulator  and Air  Inlet  on  the  bottom  of
the handle on the Spray Gun.

2. Fluid Hose Connection:  HPT-1/4 PVC Fluid Hose

with  HPTSC-Stainless  Steel  Couplings  should  be
long enough to form a loop below the Spray Gun at
all times when using fluid hose to feed material to
the Spray Gun (two required).

a.  Attach  HPTSC-1/4  St.  St.  Couplings  to  the

fluid inlets of the two Fluid Bodies.

b.  Attach  opposite  ends,  HPTSC-1/4-3/8  St.  St.

Couplings,  to  containers  of  respective
materials being sprayed.

3. Fluid Container Connection:  When using USP-QT

(QT./.946  l)  Plastic  Bottle  Assemblies,  make  sure
Screw  Covers  are  tightened  securely  so  fluid  will
not leak at Bottle connections.

4. Tighten all Air and Fluid connections securely.

OPERATION:

1. After hose connections have been made, regulate

the air pressure to about 40 lbs. atomizing pressure
and then pull trigger back slowly.

a.  The  first  1/4"  of  trigger  stroke  opens  the Air

Valve  which  operates  the  cylinder  action  of
the right side atomizing components.

b.  Continued  pull  on  the  trigger  opens  both  of

the atomizing Spray Heads for spraying.

2. The U-1460 Adjusting Nut (part 39) can be used to

regulate  desired  amount  of  fluid  to  the  automatic
Spray  Head  and  the  200-17  Fluid  Knob  (part  27)
can be used to adjust fluid to the manual side of the
two headed spray gun.

3. Dual Fluid Spray Guns are designed to atomize and

mix  fluid  materials  outside  the  atomizing  aircaps.
This  prevents  materials  from  hardening  inside  the
spray gun.

4. The  U-28-12  Packing  Washers  (part  6)  should  be

replaced periodically.

a.  Fill  packing  cavity  with  3  new  U-28-12

Packing  Washers  and  replace  U-29  Packing
Gland (part 7),   DU-30 Spring (part 8) and U-
31 Spring Seat (part 9) in position.

b.  A  few  drops  of  oil  should  occasionally  be

applied to the U-2506 Piston Leather (part Z)
to keep it pliable.

Paasche Airbrush Company

4311 North Normandy Avenue
Chicago, IL 60634-1395

Phone:

773-867-9191 

• Fax:

773-867-9198

Website:  paascheairbrush.com