background image

OWNERS MANUAL 

Congratulations on the purchase of your bathtub! 

 

MAMBO 
 

Please read and follow all the instructions contained in this Owners Manual before installing your bath-
tub. In addition, you should refer to these instructions during the life of your bathtub. 

 

 

Instruction for bathtub installation 

Only a qualified serviceman should perform the installation of your bathtub. 

 
Preparation of area 
As the front panel of the tub must be freely moved either during the installation or exploitation, choose the right area 
in which to install the bathtub. 
Prepare  the  floor  and  walls  before  installation  works.  The  corner in  which  the tub  will  be  installed,  as  well as the 
walls must be in straight angle against to floor to avoid possible gaps between tub and wall. 
The place under the tub must be in the same level as the floor. 
All drain connections should fit in between bathtub and its legs (see the drawing).  
The centre of drain is pointed in the drawing. Before assembling connections check the inlet of drainage (Ø 50 mm); 
it must be either in the same level or maximum 50 mm from the floor and not closer within a radius of 200 mm from 
the centre of bathtubs drain outlet (see the drawing). 
In case the mixers are installed on the edge of the tub outlet pipes for hot and cold water with the ½” treads must be 
arranged under the unit. 
All the models of PAA tubs and whirlpools could be installed in built-in version without front panel. For built-in ver-
sion  plan  and  provide  access  door  for  reaching  the  most  significant  massage  system  parts  (water  pump  and  air 
blower). Please consult with PAA or its dealers in these cases. 
Also  provide  the  necessary  space  around  the  water  pump and  blower to  properly ventilate  and  cool  them  during 
operation. For built-in tub there is necessary to plan ventilation access door as well. 
Electrical connection of the whirlpools 
Grounding is  required.  Connect the  tub to  230V,  50Hz  wiring  connection.  Provide  to  each  system  proper  electric 
power, choose the right crosscut cable. Use for system separate 16A differential safety catch (electric current loss 
max. 30 mA). Advised length for cable is 150 cm. 

Upon receipt, immediately inspect the bathtub to make sure the unit has shipped as ordered and 
has arrived undamaged.

 

If a problem is discovered, call your PAA dealer immediately.   

Handling damages are not covered under warranty.

 