background image

         

  

 

                                 

www.pmlighting.com 

  

                [email protected]  

 

       

      INSTALLATION INSTRUCTIONS

  

 

 

 

 

 

 

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, OR INJURY 

 

TO PERSONS IMPORTANT SAFETY INSTRUCTIONS 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION GUIDELINES – STAKE MOUNTED MODEL 

 

 

 

 

 

 

 

 

 

 

 

  

 

 

 

Save these instructions! 

For use with Low Voltage Landscape Lighting Power Units.    FOR OUTDOOR USE ONLY. 

Amperage not to exceed 25 AMPS per circuit 

Voltage not to exceed 15 VOLTS per circuit 

 

Warning:

 Luminaire must be installed in accordance with the National Electric Code (NEC) and all Local Codes. Failure 

to comply with NEC and/or Local Codes may cause serious injury and could destroy the luminaire. Failure to comply 

with NEC and Local Codes will void all warranties. 

 

Safety Warning:

 LAMP 

MAY BECOME

 HOT WHEN LUMINAIRE IS ON! Hot lamp creates risk of fire and injury to persons. 

Keep away f

rom combustibles. Turn off or unplug luminaire and allow lamp to cool to change bulb.  

Do not touch lamp with bare hands. 

Not rated f

o

r HALOGEN LAMPS

.

 

K

eep 

luminaire

away from children as luminaire may become VERY HOT. Do not install luminaire within 10 feet (3.05 

meters)

of a pool, spa, fountain, or pond. Do not cover or bury luminaire and keep luminaire clear of debris. Use only 

UL compliant components including low-voltage power units, cable, wire connectors, and any other component 

necessary. 

CAUTION: Luminaire is NOT submersible!

 

 

NOTE: Do not exceed the maximum wattage rating or maximum amperage rating of the power unit (transformer) 

used when installing multiple luminairies. 

1.

 

Disconnect or unplug transformer from power source. 

2.

 

This style of Directional Light is a complete luminaire and designed to be 
mounted on a ground stake. 

3.

 

Drive the ground stake into the ground at the desired location and depth 
(see “B”) with the included installation driver tool.  

4.

 

Connect the matching male and female terminals on the ground stake and 
luminaire, slide the socket onto the ground stake and secure the position 
desired using the brass screws on the adjustable knuckle. 

5.

 

Connect the wire terminals to the main lead to the transformer using 
included Quick Connect lead connectors. 

6.

 

Cable may be buried if desired to a maximum depth of 6 inches 
underground. 

7.

 

Do not exceed 12 Volts at the luminaire. 

8.

 

Recommended Lamp: 5W MR16 LED 

(9W LED Maximum)

 

 

Professional

 

Series  

CS937-LED Directional Lights

 

Отзывы: