SPECIFICATIONS

Engine: 

  4-Stroke, OHV, 1-Cylinder

Displacement:  

  119cc

Max. Power:  

  2,000W (2min)

Rated Power:  

  1,800W

Economy Mode Power:  500W
AC Outlets:  

  2 x 240V ~ 50Hz

Max. Current Output:   7.5A
USB Outlets:  

  5V, 1 x 1.0A, 1 x 2.1A

Fuel Capacity:  

  10L (Petrol Unleaded)

Sump Capacity:  

  0.4L

Sound Pressure Level:   77.9dB (A) @ 7m
IP Rating:  

  IP23

Weight: 

 22.0kg

IGP-2018

STANDARD EQUIPMENT

IN ORDER TO MAKE A CLAIM UNDER THIS WARRANTY 
YOU MUST RETURN THE PRODUCT TO YOUR NEAREST 
BUNNINGS WAREHOUSE WITH YOUR BUNNINGS 
REGISTER RECEIPT. PRIOR TO RETURNING YOUR 
PRODUCT FOR WARRANTY PLEASE TELEPHONE OUR 
CUSTOMER SERVICE HELPLINE:

Australia: 1800 069 486 
New Zealand: 0508 069 486

The benefits provided under this warranty are in addition to other rights and remedies which 
are available to you at law.
Our goods come with guarantees that cannot be excluded at law. You are entitled to a 
replacement or refund for a major failure and for compensation for any other reasonably 
foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the 
goods fail to be of acceptable quality and the failure does not amount to a major failure. 
Generally you will be responsible for all costs associated with a claim under this warranty, 
however, where you have suffered any additional direct loss as a result of a defective product 
you may be able to claim such expenses by contacting our customer service helpline above.

WARRANTY

TO ENSURE A SPEEDY RESPONSE PLEASE HAVE 
THE MODEL NUMBER AND DATE OF PURCHASE 
AVAILABLE. A CUSTOMER SERVICE REPRESENTATIVE 
WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS 
YOU MAY HAVE RELATING TO THE WARRANTY POLICY 
OR PROCEDURE.

OZITO 

Australia/New Zealand (Head Office) 25 Fox Drive, Dandenong South, Victoria, Australia 3175.

ozito.com.au

Inverter Generator

0321

1 YEAR REPLACEMENT WARRANTY*

Your product is guaranteed for a period of 

12 months from the original date of purchase.

 If 

a product is defective it will be replaced in accordance with the terms of this warranty. Warranty 
excludes consumable parts, for example: valve adapters and accessories.
*This product is intended for DIY use only and replacement warranty covers domestic use.

WARNING

The following actions will result in the warranty being void.

•   If the tool has been operated on a supply voltage other than that specified on the tool.
•   If the tool shows signs of damage or defects caused by or resulting from abuse, accidents 

or alterations.

•   Failure to perform maintenance as set out within the instruction manual.
•   If the tool is disassembled or tampered with in any way.
•  Professional, industrial or high frequency use.

2000W

PETROL INVERTER GENERATOR

4 STROKE 119CC ENGINE

2000W

INVERTER

TECHNOLOGY

2x

I

0

I

0

I

0

240V

1

240V

2

AC SOCKET 1

USB PORTS

AC SOCKET 2

FUEL ECONOMY

ENGINE POWER

OVERLOAD

AC OUTPUT

AC

IF OVERLOADED

RESTART ENGINE TO RESET

AUTOMATIC ENGINE SHUT OFF

REFILL MOTOR OIL

LOW OIL

OFF

ON

OFF

ON

OFF

ON

LOW OIL

AC POWER

2000W

PETROL INVERTER GENERATOR

4 STROKE 119CC ENGINE

2000W

INVERTER

TECHNOLOGY

2x

I

0

I

0

I

0

240V

1

240V

2

AC SOCKET 1

USB PORTS

AC SOCKET 2

FUEL ECONOMY

ENGINE POWER

OVERLOAD

AC OUTPUT

AC

IF OVERLOADED

RESTART ENGINE TO RESET

AUTOMATIC ENGINE SHUT OFF

REFILL MOTOR OIL

LOW OIL

OFF

ON

OFF

ON

OFF

ON

LOW OIL

AC POWER

400ml Generator Oil & 200ml Oil 
Filler Bottle

15W40 
MULTIGRADE OIL

4 STROKE OVH 119CC

ENGINE OIL

GENERATOR

OIL

400 MILLILITRES

2

1.5

1

0.5

E7RTC Replacement Spark Plug & 
Spark Plug Wrench

15W40 
MULTIGRADE OIL

4 STROKE OVH 119CC

ENGINE OIL

GENERATOR

OIL

400 MILLILITRES

2

1.5

1

0.5

Содержание IGP-2018

Страница 1: ...LICY OR PROCEDURE OZITO Australia New Zealand Head Office 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au Inverter Generator 0321 1 YEAR REPLACEMENT WARRANTY Your product is guarante...

Страница 2: ...evel before each use and top up as necessary Refer to maintenance schedule for oil replacement information 2000W PETROL INVERTER GENERATOR 4 STROKE 119CC ENGINE 2000W INVERTER TECHNOLOGY 2x AC SOCKET...

Страница 3: ...Add fuel to the tank 91 RON Unleaded Petrol Do not overfill the fuel tank check the fuel gauge on the fuel tank Do not use ethanol blended fuels Fuel tank capacity is 10L 4 After refuelling make sure...

Страница 4: ...engine power switch to the on position 3 Adjust the choke lever to suit the conditions COLD START If the weather is cold push the choke all the way right to the ON position WARM START If the weather...

Страница 5: ...ILL MOTOR OIL LOW OIL OFF ON OFF ON OFF ON LOW OIL Starting Watts aka Surge Watts You may find that even though the appliance you wish to connect to the generator is below the rated power the generato...

Страница 6: ...VERLOADED RESTART ENGINE TO RESET AC POWER I 0 0 I 0 I 240V 1 240V 2 FUEL ECONOMY ENGINE POWER AUTOMATIC ENGINE SHUT OFF REFILL MOTOR OIL LOW OIL OFF ON OFF ON OFF ON LOW OIL 1 0A USB PORTS 2 1A 2000W...

Страница 7: ...l on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not overreach Keep proper footing and balance at all times This enables better control of t...

Страница 8: ...only be passed on with these instructions Do not use in rain wet or damp environment this may lead to electrocution Always keep the generator appliances and power cords dry The electrical continuity o...

Страница 9: ...GENERATOR 4 STROKE 119CC ENGINE 2000W INVERTER TECHNOLOGY 2x I 0 I 0 I 0 240V 1 240V 2 AC SOCKET 1 USB PORTS AC SOCKET 2 FUEL ECONOMY ENGINE POWER OVERLOAD AC OUTPUT AC IF OVERLOADED RESTART ENGINE T...

Страница 10: ...SOCKET 2 FUEL ECONOMY ENGINE POWER OVERLOAD AC OUTPUT AC IF OVERLOADED RESTART ENGINE TO RESET AUTOMATIC ENGINE SHUT OFF REFILL MOTOR OIL LOW OIL OFF ON OFF ON OFF ON LOW OIL AC POWER 2 KNOW YOUR PROD...

Страница 11: ...OR 1 Frame Carry Handles 2 Recoil Starter 3 Economy Mode Switch 4 Status Indicator Lights 5 Fuel Cap 6 AC Power Socket 7 Engine Power Switch 8 USB Ports 9 Grounding Terminal 10 Oil Drain Bolt 11 AC Po...

Страница 12: ...xamine Every 2 years If necessary please change 3 WARNING SHUT OFF THE GENERATOR DISCONNECT ANY APPLIANCES CABLES BEFORE PERFORMING ANY MAINTENANCE PLACE GENERATOR ON A LEVEL SURFACE AND REMOVE SPARK...

Страница 13: ...HOT ENGINE LUBRICANT CAN RESULT IS SERIOUS BURNS 1 Use a spanner not supplied to remove the oil drain screw 2 Place a suitable container underneath the oil drain hole tilt the generator to collect th...

Страница 14: ...ng for a long period of time or if a lot of oil is in the engine Wipe up the excess oil after each use and after stopping the generator WARNING DO NOT USE PETROL OR LOW FLASHPOINT SOLVENTS FOR CLEANIN...

Страница 15: ...k the spark arrester for damage If damaged replace with replacement parts specifically designed for this unit 4 Re install the spark arrester Tighten the bolt to secure the spark arrester WARNING DO N...

Страница 16: ...d 2 Remove the spark plug using the spark plug wrench supplied by turning it anti clockwise 3 Clean the electrode with a metal brush and remove any carbon build up or replace the spark plug Set the el...

Страница 17: ...e nut using an M14 spanner not supplied whilst holding on to the fuel tap 3 Unscrew filter by hand and carefully clean with carburettor cleaner 4 Ensure the filter is dry before reattaching it to the...

Страница 18: ...generator in a vehicle If the generator is left in an enclosed vehicle for many hours high temperatures inside the vehicle could cause fuel to vaporize resulting in a possible explosion Do not operate...

Страница 19: ...start the engine and operate it in the idle position until all remaining fuel is gone and the engine stops automatically 2 Allow the generator to cool completely 3 Discharge the oil as described in t...

Страница 20: ...unqualified persons Store fuel in an approved container designed to hold fuel Store container in secure location to prevent use by others Inadequate ventilation for generator Materials placed against...

Страница 21: ...ll ventilated area Make sure hands are dry before touching unit Placing generator on or against highly conductive surface such as a steel walkway or metal roof Accidental leakage of electrical current...

Страница 22: ...uel fires Keep children or others away from the generator at all times Operating generator while suspended Generator will not operate properly and will cause damage to the generator and could cause se...

Страница 23: ...ct against damage to vehicle from leaks Remove generator from vehicle immediately upon arrival at your destination Risks From Lifting Hazard What could happen How to prevent it Lifting a very heavy ob...

Страница 24: ......

Отзывы: