THE CHARGING PROCESS:

1)  Qualification - Battery Condition Check

When the charger is first switched on it checks the battery condition to determine whether the 
battery needs reconditioning. During this qualification process it checks the internal impedance 
and initial voltage of the battery and it will determine how much charge current, if any that the 
battery will accept. It’s also senses whether the battery is still connected in the vehicle.

2)  Enhanced Battery Rejuvenation - Blue Bulk LED Flashing Fast

If the initial qualification detected that the battery was in poor condition, the patented 
rejuvenation process will begin automatically. During the rejuvenation process a high voltage 
equalising and peak pulse reconditioning charge is used to repair the sulphated battery. 
This unique patented feature will break down and dissolve the lead-sulphate crystal build up 
on the battery plates which will extend the life of your battery. It can also balance out high 
concentrations of acid. If the battery voltage doesn’t reach 9V within 24 hours, the Rejuvenation 
process will time out.

3)  Soft Start Charging - Blue Bulk LED Flashing Slow

Gently charges the battery using a reduced charge output until the battery voltages reaches 
11V. If the battery voltage doesn’t reach 11V within 6 hours, the safety timer protection will stop 
the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing.

4)  Bulk Charging - Blue Bulk LED ON

Uses the maximum charge output until the battery voltage reaches 14.4V. If the battery voltage 
doesn’t reach this within 24 hours, the safety timer protection will stop the unit from charging 
and the Red Fault LED will start flashing and the Blue Bulk LED will be ON.

5)  Absorption Charging - Green Absorption LED ON

Uses a constant voltage while reducing the charging output current to ensure the battery 
receives a full charge without overcharging the battery. 

6)  Equalisation Charging - Blue Bulk LED and Green Absorption LED both flashing 

A well proven process that carefully overcharges the battery to restore it’s full capacity.              
The Equalisation stage for AGM&WET and GEL Battery Types only occurs if the initial start 
voltage is below 11 Volts.

7)  Battery Analysis - Green Full LED ON

The battery analysis stage checks the condition of the battery after the charge cycle is 
completed. If the battery voltage drops too quickly during the analysis mode, this means the 
battery is probably faulty.  If the battery analysis failed, this is indicated by the Green Full LED 
flashing.

8)   Float Mode - Full Green LED ON

This stage allows you to keep the charger connected 24/7 to ensure your battery is well 
maintained and kept 100% fully charged. Float mode will maintain the battery at a constant 
13.6V. 

Содержание OC1204G

Страница 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Model OC1204G AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Страница 2: ...d contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger Whe...

Страница 3: ... diagnosis and charge On power up the charger will automatically diagnose the battery condition and determine if the rejuvenation mode reconditioning or charge cycle is required Patented battery rejuvenation technology The charger has a unique and patented reju venation feature which uses high voltage equalising and peak pulse reconditioning to repair sulphated batteries This feature is fully auto...

Страница 4: ...hen connect the output leads to the correct polarity SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED will come on Thispreventsthechargerfrombeingdamagedif thepositiveandnegativecrocodileclipsorringterminalsaccidentlytoucheachotherwhilethe chargeristurnedon ECO MODE This Oz Charge battery charger has a built in ultra low power...

Страница 5: ...r TECHNICAL SPECIFICATIONS Model Number OC1204G Output 4A 12V InputVoltage 100 240Vac 0 5A 65W Input Frequency 50 60Hz ChargeVoltage 14 4V EqualisingVoltage 14 6V FloatVoltage 13 6V StartVoltage 3V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 182mm x 88mm x 48mm Weight 0 75kg Approvals CE UL cUL AS NZS EMC ...

Страница 6: ...Ensure the battery is in a well ventilated area and the charger should be as far away from the battery as the cables permit STEP 2 Connecting the battery charger to your battery Simply plug the charger lead into the fly lead from your device ensuring the connector is lined up correctly and not stressed Note The plugs only fit one way and excess force is not advised STEP 3 Connecting the battery ch...

Страница 7: ...ry voltage doesn t reach 11V within 6 hours the safety timer protection will stop the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing 4 Bulk Charging Blue Bulk LED ON Uses the maximum charge output until the battery voltage reaches 14 4V If the battery voltage doesn t reach this within 24 hours the safety timer protection will stop the unit from charging and the Red ...

Страница 8: ...ies LED STATUS INDICATOR TABLE LED Status Description ChargingStatusLED s Full Green Flash ON Flashing if Analysis failed or ON if fully charged Float Maintenance mode Absor Green Flash ON Flashing during equalisation charging or ON during Absorption charging Bulk Blue Flash ON Fast Flash Rejuvenation Slow Flash Soft Start charging ON Bulk charging FaultLED Red ON Short circuit reverse polarity or...

Страница 9: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE ...

Страница 10: ...te The charger output is only present when connected to a battery No charging current Fault Red LED is Flashing Battery is severely sulphated Battery has a damaged cell Overheat protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Batte...

Страница 11: ...a copy of their receipt for proof of purchase It is recom mended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Страница 12: ...OC1204G Owner s Manual Rev 1 0 07 15 Specifications subject to change without notice SAAApproval No GMA 102826 EA 02 ...

Отзывы: