TEMPERATURE & SAFETY PROTECTION: 

• 

INTERNAL OVERHEAT PROTECTION: 

The charger has a built-in overheat and an overload 

electronic circuit. This protects the charger from being damage if overheated or overloaded 
and will automatically decrease the charging current. Once the units internal temperature 
decreases to a safe level, the charger will resume normal charging. 

• 

SAFETY TIMER PROTECTION: 

The charger has safety timers for every stage. If the battery 

voltage doesn’t reach a certain voltage within a certain time, the unit will stop charging as 
it’s highly likely that you’re attempting to charge a severely discharged or heavily sulphated 
battery. If any of the stages time out, the charger will immediately stop charging in order to 
protect the battery. This will be indicated  with the fault LED flashing slowly. 

• 

REVERSE POLARITY: 

The charger has reverse polarity protection. If the charger output leads 

are connected reverse polarity, the fault LED will come on and the charger will be disabled. 
Simply unplug  the charger from AC power and then connect the output leads to the correct 
polarity.

• 

SHORT CIRCUIT PROTECTION: 

The charger will automatically turn off if the output leads are 

short circuited and the fault LED will come on. This prevents the charger from being damaged if 
the positive and negative crocodile clips or ring terminals accidently touch each other while the 
charger is turned on.

• 

ECO MODE: 

This Oz Charge battery charger has a built in ultra low power consumption 

circuit. If AC power is connected and the battery is disconnected, after 10 seconds the charger 
will automatically go into an ECO mode. During this mode the power drawn is less than 0.36W 
which totals 0.01kWh per day power consumption. If AC power is connected and the battery 
is connected, once the battery is fully charged and during the long term maintenance stage, 
the total power consumption is around 0.03kWh per day. 

 The Power LED will flash GREEN to indicate ECO mode. 

BATTERY TYPES & CAPACITY:

• 

Suits 12V conventional lead acid batteries (VRLA) AGM, Gel & Wet.                                  

• 

The Ah (Ampere Hours) capacities shown below are to be used as a general guide only. Some 
batteries may be able to handle a higher charge current. Refer to the battery manufacturers 
specifications and recommendations for your charging requirements. 

OC1204G

Charge Rate:

4A

Charging

12 - 80Ah

Maintaining

< 120Ah

Содержание OC1204G

Страница 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Model OC1204G AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED ...

Страница 2: ...d contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the eye with running cold water for at least 10 minutes and seek medical attention Someone should always be within range of your voice Never attempt to charge a damaged battery frozen battery or non rechargeable battery Never place the charger on the battery or battery on the charger Whe...

Страница 3: ... diagnosis and charge On power up the charger will automatically diagnose the battery condition and determine if the rejuvenation mode reconditioning or charge cycle is required Patented battery rejuvenation technology The charger has a unique and patented reju venation feature which uses high voltage equalising and peak pulse reconditioning to repair sulphated batteries This feature is fully auto...

Страница 4: ...hen connect the output leads to the correct polarity SHORTCIRCUITPROTECTION The charger will automatically turn off if the output leads are short circuited and the fault LED will come on Thispreventsthechargerfrombeingdamagedif thepositiveandnegativecrocodileclipsorringterminalsaccidentlytoucheachotherwhilethe chargeristurnedon ECO MODE This Oz Charge battery charger has a built in ultra low power...

Страница 5: ...r TECHNICAL SPECIFICATIONS Model Number OC1204G Output 4A 12V InputVoltage 100 240Vac 0 5A 65W Input Frequency 50 60Hz ChargeVoltage 14 4V EqualisingVoltage 14 6V FloatVoltage 13 6V StartVoltage 3V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Size L W H 182mm x 88mm x 48mm Weight 0 75kg Approvals CE UL cUL AS NZS EMC ...

Страница 6: ...Ensure the battery is in a well ventilated area and the charger should be as far away from the battery as the cables permit STEP 2 Connecting the battery charger to your battery Simply plug the charger lead into the fly lead from your device ensuring the connector is lined up correctly and not stressed Note The plugs only fit one way and excess force is not advised STEP 3 Connecting the battery ch...

Страница 7: ...ry voltage doesn t reach 11V within 6 hours the safety timer protection will stop the unit from charging and the Red Fault LED and Blue Bulk LED will start flashing 4 Bulk Charging Blue Bulk LED ON Uses the maximum charge output until the battery voltage reaches 14 4V If the battery voltage doesn t reach this within 24 hours the safety timer protection will stop the unit from charging and the Red ...

Страница 8: ...ies LED STATUS INDICATOR TABLE LED Status Description ChargingStatusLED s Full Green Flash ON Flashing if Analysis failed or ON if fully charged Float Maintenance mode Absor Green Flash ON Flashing during equalisation charging or ON during Absorption charging Bulk Blue Flash ON Fast Flash Rejuvenation Slow Flash Soft Start charging ON Bulk charging FaultLED Red ON Short circuit reverse polarity or...

Страница 9: ...8 Oz Charge manual www ozcharge com au CHARGING CURVE ...

Страница 10: ...te The charger output is only present when connected to a battery No charging current Fault Red LED is Flashing Battery is severely sulphated Battery has a damaged cell Overheat protection mode Check the battery condition age etc Battery may need replacement Move battery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Batte...

Страница 11: ...a copy of their receipt for proof of purchase It is recom mended that returned products be sent by registered mail as Zylux Distribution Pty Ltd Oz Charge accepts no responsibility liability for goods lost or damaged in transit Exclusions If upon receiving a product for repair and if testing and examining the product has disclosed that the alleged defect or malfunction in the product does not exis...

Страница 12: ...OC1204G Owner s Manual Rev 1 0 07 15 Specifications subject to change without notice SAAApproval No GMA 102826 EA 02 ...

Отзывы: