background image

 

Praktika QL-04(K) turnstile 

 18 

Now  when  you  click  left  button  passage  will  be  allowed  to  the  right 

and vice versa. The current functions of the buttons are saved and do not 

reset when power is turned off. In order to return to the initial modification 

re-do the above sequence. 

 

8.5. Control with card collector 

 

8.5. Control with card collector 

 

The  card  collector  is  set  in  the  standby  mode  after  power-up.  It  is 

necessary to present access card to switch the mode. 

 

Passage with permanent cards  

When an authorized permanent visitor card is presented to the reader 

card  collector  unlocks  the  speedgate  for  the  time  specified  by  ACS 

controller  (depending  on  the  operating  mode;  for  5  seconds  in  pulse 

mode).  During  the  specified  time  interval  other  cards  are  not  accepted. 

When  the  passage  is  performed  or  the  specified  time  interval  is  expired 

card  collector  switches  into  standby  mode  and  can  collect  the  next  card. 

Green arrow turns on on the LED panel, indicating the authorization of the 

passage. 

 

Passage with guest cards  

Guest  card  shall  be  inserted  into  the  card  hole  up  to  the  stop 

otherwise  it  will  be  ignored.  In  case  the  presented  card  is  authorized,  the 

card collector collects it and then unlocks OD for 5 seconds. 

Содержание PRAKTIKA QL-04 Series

Страница 1: ...Operational manual www oxgard com info oxgard com 7 812 366 15 94 Praktika QL 04 K turnstile VOZROZHDENIE METALWORKS...

Страница 2: ......

Страница 3: ...tor 7 1 Card collector purpose 13 7 2 Product design 13 7 3 Removing guest cards from card collector 14 8 Speedgate operation 14 8 1 Turning on 14 8 2 Operating modes 15 8 3 Turnstile operstion with c...

Страница 4: ...04 K turnstile 4 List of abbreviations used PS power supply FA fire alarm CB control board ACS access control system OD operating device Speedgate firmware version FW v2 4 Card collector firmware vers...

Страница 5: ...hops railway stations etc To ensure easy and quick passage of people it is recommended to install one speedgate for every 500 people working in one shift 2 Delivery set Table 1 Delivery set Item Qty p...

Страница 6: ...8 107 107 25 Overall dimensions of a side unit HxWxD mm 1052 1330 510 107 107 25 Overall dimensions of two sided unit HxWxD mm 1052 1330 812 107 107 25 Weight of side unit kg 110 0 0 5 Weight of two s...

Страница 7: ...d at a nominal supply voltage optionally supplied side units required to form a passage area i e 2 power supplies units 12V 5A The manufacturer reserves the right to change the packaging technical spe...

Страница 8: ...nstile mode of passage set at the moment Indication strip is covered with tempered glass With the help of one sided and two sided units it s possible to organize unlimited number of passages depending...

Страница 9: ...ndication strip Fig 2 Inserted into the indication strip diodes are covered with tempered glass LED strip reflects turnstile mode of passage set at the moment Fig 2 LED indication strip view Control b...

Страница 10: ...during transportation and storage if Euro pallets used Keep the speedgate in dry no moisture condensation heated places within 1 to 40 C temperature range Avoid vapors of acids alkalis and corrosive g...

Страница 11: ...ate 1 The sensors are installed in the stands of speedgate at a height of 820 mm Children shorter than 820 mm cannot be identified by the speedgate Children must be accompanied by adults in charge whe...

Страница 12: ...the safety requirements specified in this section as well as terminate the product warranty IT IS NOT ALLOWED TO Set the power supply inside the speedgate housing as this might lead to electric shock...

Страница 13: ...ard collector Fig 4 is designed for collection and storage of proximity access cards at the exit from the facility Flexible logic of the controller allows the integration of the card reader with any a...

Страница 14: ...or 7 3 1 Open the hatch lock of card collector with a key Fig 4 7 3 2 Put a bag to collect cards not supplied underneath storage device 7 3 3 Lift the storage shutter to remove cards 7 3 4 Lower the s...

Страница 15: ...ic signs depicting authorization and non authorization of passage 8 3 Control with remote contron board General view of the RC panel is shown in Fig 3 Each button is equipped with the LED indicator di...

Страница 16: ...sage mode In order to swich to this mode press and hold button 1 then press button 3 and release both buttons In this mode an unlimited number of passages is allowed in both directions Arrows turn on...

Страница 17: ...various directions in relation to the user In some cases it is needed to reverse left right passage buttons This can be done by the following operations Power off the speedgate Press and hold left 1 a...

Страница 18: ...d permanent visitor card is presented to the reader card collector unlocks the speedgate for the time specified by ACS controller depending on the operating mode for 5 seconds in pulse mode During the...

Страница 19: ...collector in the standard operating mode remove cards from the storage device see Article 7 3 Emergency mode During the operation of the card collector there might be a situation when a card or a for...

Страница 20: ...Praktika QL 04 K turnstile 20 Fig 6 General view of board...

Страница 21: ...oting for speedgate Table 1 Troubleshooting for the speedgate Fault Remedy PS unit is connected but the speedgate does not work Check the connection cable Check the fuses on motherboard RC panel does...

Страница 22: ...Praktika QL 04 K turnstile 22...

Страница 23: ...Operational manual 23...

Страница 24: ...OOO 192289 66 7 812 336 15 94 www oxgard com info oxgard com...

Отзывы:

Похожие инструкции для PRAKTIKA QL-04 Series