background image

MW450 INSTALLATION MANUAL

Interface Description

Transmission Distance Reference

Item 

Part 

Feature 

Remark 

Power-On LED 

On 

Power normal 

Should power supply irregular occurs, check if POE 

switches are working properly, wiring is correct. 

Off 

Power abnormal 

Microwave Signal 

Strength Indicator 

H1 H2 H3 H4 

H1 to H4 Flashing Cycle 

Receiving normal 

 

 

Microwave Working 

LED 

Flash 

Microwave signal normal 

If the microwave power indicate abnormal, you need 

to contact the engineers, returned to factory for 

repair. 

Always On or Off 

Microwave signal abnormal 

LAN1 Working LED 

Flash 

LAN1 working properly 

When LED is Always Off & Always On, please check if 

network wiring and connectors are proper. 

Always Off 

LAN1 no access to network 

Always On 

LAN1 exception 

LAN1 Working LED 

Flash 

LAN2 working properly 

Always Off 

LAN2 no access to network 

Always On 

LAN2 exception 

LAN1 Port 

1 x RJ-45 for 10/100 Mbps

802.3at/802.3af 48V POE

 

 

LAN2 Port 

RX + 

RX - 

TX + 

DC6V – 24V 

DC6V – 24V 

TX - 

GND 

GND 

Reset 

Reset to factory default status, default IP address is 

192.168.188.253, status as MW450 mode (AP mode) 

 

 

1 set MW450 Data Receiving Capability 

Distance 

0.8km 

1.2km 

2km 

IPC qty. 

16 1080P 

8 1080P 

1 1080P 

Bandwidth 

80M 

50M 

10M 

 

1. Bandwidth and IPC quantity are reference only, above data are based on the tested data with this product and IPC at steady 
    operation, if there is an obstruction at site, or other microwave interference, then IPC quantity may need to be decreased in 
    according to the live situation.
2. 1 set of MW450R is able to receive up to 4 set MW450T data, please refer to above data table for the IPC total quantity with 4 
   set MW450 transmission, if there is an obstruction at site, or interference, 1 to 1 connection is recommended for stability.
3. Microwave relay is required if there is long distance, the total amount of data transferred depends on the distance in between 
    the last MW450T and MW450R.

H1 H2 H3 H4 I

E

M

N

R

J K

http://www.owltechcctv.com

-1-

Содержание MW450

Страница 1: ...45 for 10 100 Mbps 802 3at 802 3af 48V POE LAN2 Port N 1 RX 2 RX 3 TX 4 DC6V 24V 5 DC6V 24V 6 TX 7 GND 8 GND Reset R Reset to factory default status default IP address is 192 168 188 253 status as MW450 mode AP mode 1 set MW450 Data Receiving Capability Distance 0 8km 1 2km 2km IPC qty 16 1080P 8 1080P 1 1080P Bandwidth 80M 50M 10M 1 Bandwidth and IPC quantity are reference only above data are bas...

Страница 2: ... below Enter the IP address of microwave device with IE to enter the login screen User Name admin Password admin MW450T MW450T MW450T MW450T MW450T MW450R MW450R MW450R Computer MW450R MW450T POE Switch POE Switch NVR Router Default IP address after reset 192 168 188 253 Factory IP address shown at device label Computer IP address set with the same network segment of Microwave device 192 168 1 188...

Страница 3: ...and password as well as microwave frequency band http www owltechcctv com 3 1 Modify SSID name set up in according to installation location and other information to facilitate future maintenance Each device needs to be set to a different name Suggested name project location IP address information 2 Channel width of 10M 20M 40M 80M selectable factory default value is 40M modification is not recomme...

Страница 4: ...oose set up the band in according to the frequency band environment analysis 1 band interval with existing bands is suggested 5 Modify the encrypted password Note remember the settings for 2 3 4 and 5 are the same to corresponding MW450R and MW450T Step 5 Set up AP WDS ...

Страница 5: ...rd admin MW450T MW450R Computer POE Switch Default IP address after reset 192 168 188 253 Factory IP address shown at device label Computer IP address set with the same network segment of Microwave device 192 168 1 188 2 Gateway set 192 168 188 1 Noted that when doing MW450T setting make sure MW450R setting is completed and powered Need to know the SSID and passwor of such MW450R but should not be...

Страница 6: ... after modification login again Step 4 Set up device name and password as well as microwave frequency band Set up AP WDS 1 Modify SSID name set up in according to installation location and other information to facilitate future maintenance Each device needs to be set to a different name Suggested name project location IP address information Note settings 2 3 5 are the same as the settings of corre...

Страница 7: ...ce to pair with the MAC address of MW450T max up to 4 MW450T Step 2 Enter MW450T setup interface to pair with the MAC address of MW450R note that only 1 MW450R Check the signal connection strength of MW450T and MW450R this parameter can be used as reference for angle adjustment during installation ...

Страница 8: ...be above DC12V 2A Pin 1 2 3 6 4 5 7 8 Wire Color White Orange Orange White Green Green Blue White Blue White Brown Brown Signal RX RX TX TX DC6 24V DC6 24V GND GND MW450R T MW450R T POE Switch Method 1 connected to POE switch directly 1 2 3 6 4 5 7 8 DC6V 24V GND http www owltechcctv com 8 Switch Not POE ...

Страница 9: ...50 at the same time power need to be above DC12V 4A MW450T MW450R POE Switch Pin 1 2 3 6 4 5 7 8 Wire Color White Orange Orange White Green Green Blue White Blue White Brown Brown Signal RX RX TX TX DC6 24V DC6 24V GND GND MW450T MW450R 1 2 3 6 4 5 7 8 DC6V 24V 4 5 7 8 GND http www owltechcctv com 9 ...

Отзывы: