MW450 INSTALLATION MANUAL
Interface Description
Transmission Distance Reference
Item
Part
Feature
Remark
Power-On LED
E
On
Power normal
Should power supply irregular occurs, check if POE
switches are working properly, wiring is correct.
Off
Power abnormal
Microwave Signal
Strength Indicator
H1 H2 H3 H4
H1 to H4 Flashing Cycle
Receiving normal
Microwave Working
LED
I
Flash
Microwave signal normal
If the microwave power indicate abnormal, you need
to contact the engineers, returned to factory for
repair.
Always On or Off
Microwave signal abnormal
LAN1 Working LED
J
Flash
LAN1 working properly
When LED is Always Off & Always On, please check if
network wiring and connectors are proper.
Always Off
LAN1 no access to network
Always On
LAN1 exception
LAN1 Working LED
K
Flash
LAN2 working properly
Always Off
LAN2 no access to network
Always On
LAN2 exception
LAN1 Port
M
1 x RJ-45 for 10/100 Mbps
(
802.3at/802.3af 48V POE
)
LAN2 Port
N
1
RX +
2
RX -
3
TX +
4
DC6V – 24V
5
DC6V – 24V
6
TX -
7
GND
8
GND
Reset
R
Reset to factory default status, default IP address is
192.168.188.253, status as MW450 mode (AP mode)
1 set MW450 Data Receiving Capability
Distance
0.8km
1.2km
2km
IPC qty.
16 1080P
8 1080P
1 1080P
Bandwidth
80M
50M
10M
1. Bandwidth and IPC quantity are reference only, above data are based on the tested data with this product and IPC at steady
operation, if there is an obstruction at site, or other microwave interference, then IPC quantity may need to be decreased in
according to the live situation.
2. 1 set of MW450R is able to receive up to 4 set MW450T data, please refer to above data table for the IPC total quantity with 4
set MW450 transmission, if there is an obstruction at site, or interference, 1 to 1 connection is recommended for stability.
3. Microwave relay is required if there is long distance, the total amount of data transferred depends on the distance in between
the last MW450T and MW450R.
H1 H2 H3 H4 I
E
M
N
R
J K
http://www.owltechcctv.com
-1-