background image

OWI User Manual: Model 2X2-ER2TR61 

OWI INC.                                                    7                                             www.owi-inc.com 

 

Energy Star Sleep Mode 

 
If  no  audio  is  present  on  any  input  of  the  power  amplifier,  the  amplifier  goes  into  a  low  power 
“shutdown,  or  sleep  mode”  within  30  minutes.   During  sleep  mode,  power  consumption  of  the 
power supply and the amplifier is less than one (1) watt. 

 
Two (2) audio inputs: Line In and Jack Line In 

 
The 

LINE IN

 inputs accepts a balanced input via a Phoenix style screw terminal plug. The JACK 

LINE IN accepts unbalanced input via 3.5 mini jack. The mini jack accept stereo inputs. The stereo 
channels are summed together. This input is muted during Priority Override. 
 

 

Priority Override Feature 
 

The 

Priority

  input  accepts  balanced  input  levels  of  resistor  selected  100  volts  audio,  70  volts 

audio,  25  volts  audio  and  1  volt  (approximately  line  level)  audio.  Audio  on  the 

Priority

  input 

suspends audio on the 

Line In and Jack Line In

 inputs and switches the speaker amplifier to pass 

the 

Priority 

audio.

 

After the 

Priority

 audio stops, the unit waits before returning to the 

Line In and 

Jack Line In 

audio input.  

 

Balanced Line Level Output 

 
A nominal 0dB level, balanced output is available at LINE OUT. The source of this output  is both 
balanced and Jack Line In sources. 
 

Power Amplifier Features 

 
The power amplifier outputs 2 times 20 watts or 40 watts total into 8 ohms and 15VDC power. The 
class D power amplifier has reduced radiated electromagnetic interference (EMI) due to a special 
feature  of  the  power  amplifier,  operating  in  a  patented  spread  spectrum.  The  power  amplifier 
protects  itself  from  over-temperature,  over-current,  over-voltage  conditions.  The  power  amplifier 
will shut itself down during these conditions. 
 

 
 
 
 
 
 
IMPORTANT NOTE!  This amplifier is intended for audio use only! Continuous sine wave drive 
into a load will cause the amplifier to shut itself down when it heats up.

 

Содержание 2X2-ER2TR61

Страница 1: ...R2TR62 2X2 ER2TR64 2X2 ER2TR61SVC 2X2 ER2TR62SVC 2X2 ER2TR64SVC MULTI VOICE COIL WITH ER PAGING OVERRIDE Established 1978 OWI Incorporated 17141 Kingsview Ave Carson CA 90746 1207 USA Tel 310 515 1900...

Страница 2: ...fication improperly serviced or accidentally damaged 4 OWI Inc shall have no liability whatsoever for consequential damages The sole responsibility at the discretion of OWI Inc under this warranty sha...

Страница 3: ...y Information 2 Return Shipping Instructions 2 Table of Contents 3 Important Safety Instructions 4 5 Introduction 6 Specifications 7 9 Illustration Connection and Control 10 Chained Self Amplified Spe...

Страница 4: ...hall not be exposed to dripping or splashing and that no objects filled with liquids such as vases shall be placed on the apparatus IMPORTANT SAFETY INSTRUCTIONS 1 Read these instructions All the safe...

Страница 5: ...roduct beyond those means described in this operating manual All other servicing should be referred to the OWI Service Department 15 WARNING To reduce the risk of fire or electric shock do not expose...

Страница 6: ...th an included UL Listed Level 5 Energy Star 15 volt 3 5 ampere power supply the amplifier can output 40 watts or 10 watts per speaker in a four speaker hook up Special features of the OWI Model 2X2 E...

Страница 7: ...io on the Priority input suspends audio on the Line In and Jack Line In inputs and switches the speaker amplifier to pass the Priority audio After the Priority audio stops the unit waits before return...

Страница 8: ...ent operating 15VDC 1 667 amperes peak Input volt amperes peak 15VDC 25 volt amperes Input voltage maximum 16 5 volts DC Frequency Response EQ set to flat 50Hz to 15 kHz Bass 10dB 50Hz Treble 10dB 10k...

Страница 9: ...volt supply with a 22 volt supply and Energy Star and UL approvals no longer apply Power Supply Wire Gauge and Length Minimum 18 gauge up to 40 feet maximum length NON AMPLIFIED SPEAKER IC6 DESCRIPTIO...

Страница 10: ...OWI User Manual Model 2X2 ER2TR61 OWI INC 10 www owi inc com Illustration Connection and Control 2X2 ER2TR61 2X2 ER2TR61 With 2570TR transformer...

Страница 11: ...ser Manual Model 2X2 ER2TR61 OWI INC 11 www owi inc com 2X2 ER2TR61 TO ANOTHER 2X2 ER2TR61 SPEAKER WIRING SINGLE LINE DIAGRAM Chained Self Amplified Speakers Wiring One Two Four Speaker Combination Wi...

Страница 12: ...OWI User Manual Model 2X2 ER2TR61 OWI INC 12 www owi inc com...

Страница 13: ...OWI User Manual Model 2X2 ER2TR61 OWI INC 13 www owi inc com INPUT CONNECTORS WIRING Note Jack Line In is the same as STEREO LINE IN immediately below...

Страница 14: ...OWI User Manual Model 2X2 ER2TR61 OWI INC 14 www owi inc com VOLUME CONTROL WIRING DIAGRAM...

Страница 15: ...e placement carefully taking into effect the location of electrical plumbing and other fixtures Placement in Ceiling OWI speakers should be located above the primary listening area Mounting your OWI s...

Страница 16: ...liability whatsoever for consequential damage The sole responsibility and discretion of OWI Inc under this warranty shall be limited to the repair of the product or replacement thereof 6 IMPORTANT Th...

Страница 17: ...OWI User Manual Model 2X2 ER2TR61 OWI INC 17 www owi inc com Established 1978 OWI Incorporated 17141Kingsview Ave Carson CA 90746 1207 USA Tel 310 515 1900 Fax 310 515 1606 www owi inc om 091715...

Отзывы: