Содержание AirLive Ether-FSH2400NS

Страница 1: ...Ether FSH2400NS Smart Fast Ethernet Switch Windows In Band Management 24 10 100Base TX ports Auto MDI MDI X VLAN Priority Bandwidth Control Trunking Loop Detection User s Manual...

Страница 2: ...ith this guide may cause significant interference with radio communication Operation of this equipment in a residential area is likely to cause interference to household appliances in which case the u...

Страница 3: ...gement 1 VLAN filter 1 Quality of Service 1 Link aggregation 1 IGMP Snooping 1 Broadcast Storm control 1 Loop detection 1 Port setting 2 Authentication Keys 2 In Band and Out of Band Management 2 What...

Страница 4: ...tallation 7 5 Steps to Quick Installation 7 Rack Mounting 7 Desktop Installation 8 Installation Site Preparation 8 Cabling Guide 9 For 10 100BASE TX ports 9 Auto MDI MDI X function 9 Making your own U...

Страница 5: ...Quality 21 Switch Configuration 21 Global Configuration Submenu 22 Loop Port Detection 22 Port Configuration Submenu 23 Trunking 24 Qos Configuration Submenu 24 VLAN Configuration Submenu 26 Port Bas...

Страница 6: ...2 3 The Reset Button 5 Fig 2 4 Rear Panel 6 Fig 3 1 Fastening the brackets on the switch 7 Fig 3 2 Attaching the Switch to a 19 inch rack 8 Fig 3 3 Desktop installation 8 Fig 3 13 Connecting the Switc...

Страница 7: ...Table of Contents Tables Table 2 2 Cabling type for 10 100BASE TX 9 Table 4 1 System Station Port LEDs 13 v Ether FSH2400NS Fast Ethernet Switch User s Manual V1 0...

Страница 8: ......

Страница 9: ...t bandwidth control allow limiting the outgoing and incoming bandwidth separately for each port Central Switch management Configure several switches at the same time VLAN filter provide controls to le...

Страница 10: ...e RRCP protocol that enables the included Windows utility to manage the switch inside the LAN However since it does not use IP protocol it cannot be managed remotely from the Internet What is VLAN Def...

Страница 11: ...etting by any of the three types of priority frames operations TCP IP TOS or per Port priority frame operation The QoS setting for priority per port means that all packets received by the port will be...

Страница 12: ...3 Put back all the shipping materials such as plastic bag paddings and linings into the package carton and save them for future transport need After unpacking and taking out the entire package conten...

Страница 13: ...Features a reset button that can restore the switch settings back to factory s default value Please press this button if your management software have problem detecting the switch or if the switch is...

Страница 14: ...ould be attached Just plug the female end of the power cord into the connector and the male end of the power cord into an AC power outlet The switch supports an input voltages ranging from 100 240 VAC...

Страница 15: ...mounted on a standard size 19 inch rack which can in turn be placed in a wiring closet with other equipments Before you can mount the switch on the rack first you must attach the mounting brackets on...

Страница 16: ...work may greatly affect its performance Installation Site Preparation You can mount Ether FSH2400NS Fast Ethernet Switch either on desktop or on a 19 inch rack If you plan to mount the switch on deskt...

Страница 17: ...TP cable for connection When configuring within the 10 100BASE TX cabling architecture the cable distance should be within 100m The following table summarizes the cable requirement for 10 100BASE TX c...

Страница 18: ...d together before inserting into the jack Incorrect twisted pair will cause the cable to malfunction or signal degradation over short distance Fig 2 4 Pair Wires Fig 2 3 Twisted Pair Color Scheme A st...

Страница 19: ...3 Installation of the Switch Power Switch Power Connector Power Outlet Fig 3 13 Connecting the Switch to power outlet 11 Ether FSH2400NS Fast Ethernet Switch User s Manual V1 0...

Страница 20: ...twork You can use the management program s diagnostic function to find out which port the loop occurs This function will work only after you enabled the Loop Detection using the Management Utility Tru...

Страница 21: ...detected Trunk link is established Trunk function is turn on but connection is wrong Station Port LEDs Link Rx Green ON Blinking OFF Connection is made Transmitting Receiving No connection is made FD...

Страница 22: ...the management software Most of the setting options show up when you right click on the screen using your mouse Please make sure to press the Apply button after changes Please make sure to write to th...

Страница 23: ...Explorer please click on setup exe to begin 2 Click on ETHER SNMP Series and select the Ether FSH2400NS 3 Follow the instruction on screen to install the WinPCap You only have to install it once If yo...

Страница 24: ...CD ROM 2 The follow screen will appear Please select a network interface card choose the one that has a IP address and select a switch from the pull down menu After you select the switch configuratio...

Страница 25: ...o please right click on the switch Then select Add to Switch Database You can give a name to the switch and change the password during the process 4 You can also manually enter a switch by click on th...

Страница 26: ...nternals We will discuss them in the following sections Please make sure to save to the hardware after changes Switch Status Functions Click on the Switch Status Tab of the management screen will brin...

Страница 27: ...g TX Receiving RX and diagnostic packets separately Furthermore you can even choose to monitor all packets or just collision error packets Please remember to right click each port to change units Star...

Страница 28: ...umber of CRC Error Collision Packet The MIB information show the number Collision Packet Cable Tester The cable tester function tests the quality of the cable and whether the cable length has exceed t...

Страница 29: ...This test whether the electrical signal on each port is good or bad Switch Configuration Choose the Switch Configuration menu will bring various configuration submenus for the switch 21 Ether FSH2400...

Страница 30: ...e loop detection function please enable this option and save settings to the switch Once this function is enabled the Loop LED will light up when there is a loop formed in your network IGMP Snooping S...

Страница 31: ...ss the Port Configuration submenu and you will see a dialog like follows Put the check in the item you want to configure To Configure please right click on a port Then the following menu will appear 2...

Страница 32: ...ol Enable or Disable the pause frame from control The default is enabled for both RX TX This option needs to be enabled for the Rate Control to work Trunking Enable the Trunking group for this particu...

Страница 33: ...priority contrl Adapter Flow Control To disable or enable using the adapter flow control High Low Piority Ratio The number of high priority packet passed before letting a low priority packet go For e...

Страница 34: ...lect Port Base VLAN The 802 1Q VLAN is not supported Unicast Packet Leaky When enabled Uni Cast packets are allowed to travel outside a particular VLAN ARP Packet Leaky When enabled ARP packets are al...

Страница 35: ...LAN ADD A New VLAN Please right click your mouse on the white area to add a new VLAN Once you do a new windows will pop out asking you to select the VLAN ports Modify or Remove a VLAN Group Please rig...

Страница 36: ...mainly used for diagnostic purpose It allows the administrator to listen to the traffic of other ports In another words it will copy the traffic from the mirrored port to the mirroring port Adding a...

Страница 37: ...administrators to control which port can do the management function If you want to change the administration password for the switch please see page 17 Network Add Switch menu for more details Please...

Страница 38: ...to factory s default settings Save Configuration to Hardware Press this setting to save configurations into the switch s memory The management utility will also ask you to do so when you want to close...

Страница 39: ...ASE TX Port Auto MDI MDI X Data Rate 10BASE T Ethernet 10 Megabits sec half duplex 20 Megabits sec full duplex 100BASE TX Fast Ethernet 100 Megabits sec half duplex 200 Megabits sec full duplex Trunki...

Страница 40: ...ble LED layout System LEDs Power LED Loop LED Trunk LED Station port LEDs for port 1 24 Link Act LEDs FDX Col LEDs 100M LEDs Dimensions 330 162 44 mm Net Weight 1 6 kg Power Input Internal universal p...

Страница 41: ...nd node does not exceed 100 meters for 10 100BASE TX connection Make sure that the maximum switch to hub switch cable distance does not exceed 100 meters for 10 100BASE TX connection Verify that the c...