RONDA 200

Industrial vacuum cleaner for dust hazardous to health

Congratulations with your new RONDA  200 Industrial vacuum cleaner from Overmat Industries B.V.

 RONDA 200 is an industrial vacuum cleaner developed to collect very fine dust and dust hazardous to health. 

 RONDA 200 meets the requirements for a handy industrial vacuum cleaner in the building and construction 

industry. It is ideal to collect fine hazardous dust such as cement or dust from grinding machines.

The RONDA 200 is superb in connection with the use of handheld electrical tools. 

Self-cleaning Teflon-coated tube-filter (BIA Dust 

class ”M”)

Filter-cleaning during operation

Monitoring suction-power during operation

HEPA-filter (BIA Dust class ”H”)

Splash proof according to IPX4 (IEC 60 529)

Conformity with EN 60 335-2-69:1998 Annex AA 

for collecting dust hazardous to health in Dust 

class ”H”

Average emission during recognized test with 

quartz-dust 0,06 mg/m

3

Holds back 99,999% of all particles larger than 

0,3

µ

m (0,0003 mm)

Dust-collecting in double layer filter bag with 

patented sealing system for dust hazardous to 

health, in classic P10 filter bag or directly in the 

dust container

Electrical power take-our with automatic start/stop 

V

V

A

A

C

C

U

U

U

U

M

M

C

C

L

L

E

E

A

A

N

N

E

E

R

R

S

S

F

F

O

O

R

R

F

F

I

I

N

N

E

E

D

D

U

U

S

S

T

T

-

-

R

R

E

E

F

F

.

.

9

9

3

3

9

9

8

8

5

5

1

Содержание RONDA 200

Страница 1: ...f cleaning Teflon coated tube filter BIA Dust class M Filter cleaning during operation Monitoring suction power during operation HEPA filter BIA Dust class H Splash proof according to IPX4 IEC 60 529 Conformity with EN 60 335 2 69 1998 Annex AA for collecting dust hazardous to health in Dust class H Average emission during recognized test with quartz dust 0 06 mg m3 Holds back 99 999 of all partic...

Страница 2: ... Container capacity 16 l Plastic sack with filterbag 14 l Height 780 mm Length 425 mm Width 425 mm Weight without accessories 15 kg Container coupling Ø40 mm RONDA 200 meets the requirements in EN 60 335 2 69 1998 Annex AA concerning the collecting of dust hazardous to health in Dust class H Vacuum cleansers for the collection of dust hazardous to health must be marked as follows WARNING This appl...

Страница 3: ... hose and all the necessary nozzles Accessories can be re ordered using the following part numbers 1 40 mm Professionals set 2 Hose 4 m 3 Crevice nozzle 4 Adaptor for furniture nozzle 5 Furniture nozzle 6 Round brush 7 Floor nuzzle B 370 with brush and wheels 8 Tubes 3 2 1 4 5 6 7 8 3 ...

Страница 4: ... filter is an integrated part of the motortop The HEPA filter is classified as a Dust class H filter The filter holds back the finest and smallest dust particles that are not held back by the tube filter The HEPA filter holds back particles of the size of only 0 3 µm 0 0003 mm The filter surface it self is 1 1 m2 large and is protected by a metal framework Motortop with manometer and pressure reli...

Страница 5: ...f cleaning effect during operation The filter consists of a number of tubes mounted on springs During operation the tubes vibrate and part of the dust sucked on to the tube surface falls down in the dust container Dust container and filter bag The dust container is equipped with five pivotally wheels The dust container contains the filter bag and the plastic sack for the collection of dust hazardo...

Страница 6: ...his manual RONDA 200 may be used for collection of dust hazardous to health according to CEI IEC 60335 2 69 Annex AA The user must ensure that the appliance is adjusted for the task and that statutory requirements are met When collecting dust hazardous to health the P10 filter bag together with the protecting plastic sack must be used in order to secure dust free emptying Connect the appliance to ...

Страница 7: ... the majority of the particles The tube filter holds back all the particles that are larger than 0 005 mm as well as most of the particles less than 0 005 mm The finest particles are held back bye the HEPA filter under the motortop The HEPA filter holds back 99 999 of all particles larger than 0 0003 mm The cleaned air continues through the suction motor and is led through the exhaust filters and ...

Страница 8: ... sure the filters are not damages Also see the chapter Replacing filters Use the filter bag with plastic sack if dust hazardous to health is being collected Make sure that the electrical main supply cord and plug are not damaged Is the cord and or the plug damaged it must be replaced by an original cord or plug Connect the appliance to 230 V power supply with a reliable connection to earth Make su...

Страница 9: ...e wheel height using the knob to secure that the brushes only just touches the floor Power take out and automatic start stop RONDA 200 is equipped with a power take out socket with automatic start stop Connecting electrical hand held tools to the power take out on the motortop makes it possible to turn the RONDA 200 on and off with the on off switch on the hand held tool The power take out is prog...

Страница 10: ...ide the appliance during operation If the tube filter is blocked by fine particles the air pressure inside the appliance will drop The manometer will indicate the drop in air pressure By reaching the red section the pointer indicates that the air velocity in the hose is to low and that the tube filter needs to be cleaned The tube filter is cleaned during operation Release the hose from the pipe Pr...

Страница 11: ...t the same time fresh air floats the opposite way through the tube filter in order to equalize the pressure in the dust container and in the hose In this way the tube filter is cleaned in an effective way The effect of the cleaning process can be seen on the manometer If necessary repeat the filter cleaning process until the pointer of the manometer re enters the green section It is advisable to l...

Страница 12: ... of polluting the environment during the emptying process is reduced Release the motortop by releasing the four clips securing the motortop on the dust container Place the motortop on a dry and clean surface Pull out the tube filter using the two handles Gently place the tube filter on a dry clean and horizontal surface Have no filter bag been used the dust container can now be emptied If filter b...

Страница 13: ...er bag P10 in the dust container Wrap the collar of the filter bag around the coupling in the dust container Remount the tube filter and the motortop Collecting dust hazardous to health the filter bag with plastic sack must be used to secure dust free emptying Wrap the collar of the filter bag around the coupling in the dust container Pull the plastic sack aside so it does not cover the filter bag...

Страница 14: ... appliance with a wet or dry cloth Maintenance of the motortop The motortop is manufactured from maintenance free parts and needs no daily maintenance apart from external cleaning as described above A daily inspection of the electrical cord and plug is advisable to avoid electrical hazards and accidents Wipe the outer surface of the motortop with a wet or dry cloth To secure the reliability of the...

Страница 15: ...by all the small particles Consequently the filter must be checked for holes and fissures on a regular basis Even small holes in the tube filter will allow particles to penetrate the filter and then be held back in the HEPA filter The HEPA filter is designed for very small particles and will rapidly be blocked if the tube filter is damaged Release the motortop by releasing the four clips securing ...

Страница 16: ...HEPA filter make sure that the surface of contact between the HEPA filter and the motortop is clean Tighten the screw so the HEPA filter is secured under the motortop The bottom of the HEPA filter is made of a thin metal material so be sure not to tighten the screw too much Disposal of used filters When disposing used filters make sure that they are disposed according to the guidelines given by lo...

Страница 17: ...ock the suction hose Normally a leak can be located by its characteristic sound Dismount the motortop and inspect the area where the leak was located Make sure that the surfaces of contact are clean and remount the motortop Repeat the operation if necessary The filter bag may be blocked The filter bag cannot be completely filled if very fine dust is collected Replace the filter bag The tube filter...