SnapSAN YSS User Guide
10400401-001 08/2012
©2012 Overland Storage, Inc.
4-3
Sample output:
MV: Disk No.-
LD Namemv001
Type WN Volume Name- Path-
RV: Disk No.2
LD Namerv001
Type WN
Volume Name\\?\Volume{91eaf297-4e8a-11d9-861c-505054503030}\ Path-
Activity Stateseparate Sync State separated Copy Control State-
Separate Start Time2004/12/24 14:24:53
Separate End Time2004/12/24 14:24:53
Separate Diff32KB Copy Diff 0KB RV Accessrw
Previous Activesep/exec
2.
If “Activity State” of the RV is “replicate”, it is necessary to separate the RV from the
MV. This is executed here using the settings below. If “Activity State” of the RV is
“separate”, the command below need not be executed.
•
Access restriction for RV after separated: rw (Read/Write) (Default value)
•
Specify wait for separation to complete
> iSMrc_separate -mv mv001 -mvflg ld –rv rv001 –rvflg ld -wait
3.
If “RV Access” of the RV checked in (2) is other than “NA”, stop the volume beforehand
in order to change the RV access restriction to Not Available (NA). Here, the setting is
made for logical disk name rv001.
> iSMvss -devmode disable -vol rv001 -volflg ld
If the target volume is already stopped, the message below is output. Proceed to execute
the procedure in (5).
iSMvss: Err:iSM20519: Specified disk cannot be disabled.
4.
Change the RV data state to invalid and the RV access restriction to Not Available
(NA). Here, settings are made for logical disk name rv001.
> iSMrc_rvmode -rv rv001 -rvflg ld -rvdata invalid -rvacc na -force
The above is the end of the volume initialization procedure for operation using the data
replication function.
Collecting Information of Unclear Failure
Even when performing the procedures above, if an error occurs during backup, execute the
commands in the procedure below to gather an operation trace and other fault information.
Login as Administrator.
1.
Click the Windows [Start] button, and select and execute [All Programs]
→
[ControlCommand]
→
[SnapSAN Manager Volume List]
→
[Difficulty Information
Gather]. When changing the directory of the storage destination and executing,
specify a directory on the appropriate server and do not specify a directory on a
separate server connected by a network.
2.
Confirm that the iSMvolgather directory is created under the installation directory
when the storage destination directory is not changed or under the specified directory
when it is changed, and obtain the files under that directory.