10400414-002 05/2013
©2013 Overland Storage, Inc.
3-15
SnapSAN S5000 Data Migration User Guide
iSMmc_pair -delete command execution example:
# iSMmc_pair -src EXP167_DATA_1 -srcflg ld -dst EXP167_DATA_1_NEW -
dstflg ld -delete
iSMmc_pair: Info: iSM36005: Pair Delete Start 2011/11/19 22:36:00
SRC:EXP167_DATA_1
iSMmc_pair: Info: iSM36006: Pair Delete Normal End 2011/11/19
22:36:02 SRC:EXP167_DATA_1
iSMmc_pair: Info: iSM36001: Command has completed successfully.
ExitStatus:0
# iSMmc_pair -src EXP167_LOG_1 -srcflg ld -dst EXP167_LOG_1_NEW -dstflg
ld -delete
iSMmc_pair: Info: iSM36005: Pair Delete Start 2011/11/19 22:36:03
SRC:EXP167_LOG_1
iSMmc_pair: Info: iSM36006: Pair Delete Normal End 2011/11/19
22:36:05 SRC:EXP167_LOG_1
iSMmc_pair: Info: iSM36001: Command has completed successfully.
ExitStatus:0
Changing Access Control
6.
Connect the application server and the destination disk array through FC.
* This step is not necessary if the application server and the destination disk array
have been already connected during
the pre-migration processing.
7.
Create new LD sets on all the servers with the Access Control function on the iSM
client screen (GUI) or the CLI (iSMCLI) in the destination disk array and assign the
migrated logical disks on the destination disk array to the application server.
8.
Select
[Bind] >
[Assign to host]
from the main window menu of SnapSAN Manager
Embedded or SnapSAN Manager to open the allocation to host screen.
9.
Select the allocation destination server and the logical disks to be allocated to the
server and select the [Next] button.
10.
Confirm the setting and select the [Run] button. After the process is complete, select
the [Complete] button.
Starting the server (application server)
1.
Start the application server previously shut down in
2.
Recognize the device and test it (application server * target: destination disk array).
3.
Check that the OS recognizes the destination logical disk and restore operations.
4.
Check that the OS recognizes the destination logical disk. If the destination logical
disk is not recognized, make the OS recognize it.
For Windows
a.
Update disk information by executing [Rescan disk].
b.
Make the disk online if it is offline.