Troubleshooting
5-3
F
AULT
S
YMPTOM
C
ODES
(FSC)
Fault Symptom Codes (FSC)
If a fault persists, look up the FSC in the following table and call your Technical Support
Representative
Table 0–1 Fault Symptom Codes
FSC
Message
Description
ERP
0101
Unused Interrupt
Enter to Reboot or
Power Down to Clear
Firmware error - HARD fault - the code tried to
execute an un-initialized (unused) interrupt vector.
C, D, G
0102
Enqueue'g a Null Ptr
Enter to Reboot or
Power Down to Clear
HARD fault - a request was made to add a NULL
pointer to a message queue.
C, D, G
0103
Invalid Cmd Rec'd
Enter to Reboot or
Power Down to Clear
HARD fault - This library is configured as a slave and
has received an illegal command from the remote
master. This cannot happen with LTO loaders.
C, D, G
0201
Trc. Comm Open Error
Enter to Reboot or
Power Down to Clear
HARD fault - Unable to open the trace serial port. The
loopback test of the baud rate divisor registers or one
of the "expected 0" bit tests failed.
C, D, G
0301
Novram Init. Error
Enter to Reboot or
Power Down to Clear
HARD fault - The firmware was unable to write data to
the novram during initialization.
C, D, G
0302
Novram Chksum Error
Press Enter to Init
Novram to Def. Cfg.
SOFT fault - The novram checksum did not match the
data. The novram needs to be re-initialized.
F
0303
Novram Program Error
Enter to Reboot or
Power Down to Clear
HARD fault - The firmware was unable to write data to
the novram during an edit operation.
C, D, G
0304
Novram Downld. Error
Press Enter to Clear
SOFT fault - The system was unable to import data
from the serial port to update the novram. The
novram contents are unchanged.
F
0305
Novram Data Error
Press Enter to Clear
SOFT fault - The novram checksum did not match the
data during a validation check.
F
0306
Novram Update Error
Enter to Reboot or
Power Down to Clear
HARD fault - The novram did not update properly. The
checksum and data no longer match.
C, D, G
0401
Invalid Display Char
Press Enter to Clear
Firmware err - SOFT fault - width spec of %d or %x
format was outside the range {1…9} in a lcdPrintf call.
F
0402
Invalid Display Line
Press Enter to Clear
Firmware err - SOFT fault - an lcdPrintf() request was
made to print to a non-existent display line
(outside{0..3} range).
F
Содержание LoaderXpress
Страница 1: ...Part No 104249 102 04 2004...
Страница 3: ......
Страница 5: ...xii...
Страница 6: ...xiii...
Страница 12: ...1 6...
Страница 16: ...2...
Страница 22: ...1 6 Introduction TAPE CARTRIDGE MAGAZINES...
Страница 50: ...2 28 Installation CONFIGURATION OPTIONS DESCRIPTIONS...
Страница 98: ...5 20 Troubleshooting USING THE DEMO SUBMENU...
Страница 102: ...A 4 FCC NOTICE Declaration of Conformity...