30
Installation
Unibox T-RTL R-Tronic
102273780-V01.09.2019
6. Installation
6.1 General installation advice
Note the following prior to installation:
•
The lower edge of the "Unibox T-RTL
R-Tronic" must be at least 20 cm above the
finished floor.
• The front face of the "Unibox T-RTL R-Tron-
ic" must be level with the finished wall.
Should the wall not have been
finished, take the plaster and tile
thickness into account.
•
The opening of the wall box unit must face
downwards.
•
The thermostat must not be influenced by
other heat sources.
•
Use the enclosed brackets to align and fix
the "Unibox T-RTL R-Tronic".
•
There is a blue dot on the wall box unit. A
hole can be drilled at this location in order
to feed through a cable.
• If necessary, use an empty pipe for cable
routing.
NOTICE
Risk of damage due to lubri-
cants
Seals may be destroyed by greasing
agents or oil.
f
Do not use any greasing agents or
oil for the installation.
f
Flush any dirt particles or grease or
oil residues out of the pipework.
f
Consider the latest technical status
(e.g. VDI 2035), when choosing the
operating fluid.
1
2
3
4
5
6
7
Illust. 7: Installation cross section
(1)
Block or stud wall
(2)
"Unibox T-RTL R-Tronic"
(3)
Plaster
(4)
Pipe conduit unit (separate accessory)
(5)
Edge insulating strip (separate acces-
sory)
(6)
Screed
(7)
Protective tube (separate accessory)
6.2 Installation of the "Unibox
T-RTL R-Tronic"
DANGER
Danger to life due to electric
current
Danger to life due to contact with live
components.
f
The electrical connection must
only be carried out by a qualified
electrician.
The "Unibox T-RTL R-Tronic" must
always be located at the end of the
surface temperature balance circuit
(see 3.3 on page 27).