OVM_FT-0113
8
Red Screen Displayed when Starting A Cook
Red Screen
Displayed When
Starting A Cook
Was the cook
cancelled with the
“Open” button?
Cook was not
cancelled with the
“Open” button
Cook was
cancelled with the
“Open” button
This
is normal.
Follow
onscreen
prompts
Verify that the cook
surface is on the same
side as the touchscreen
being used
Proper
touchscreen is
being used
Wrong
touchscreen is
being used
Use the
correct
touchscreen
Assure that the
slider is at its end of
travel by looking at
alignment of doors
and cavity
Slider is not at the
end of travel
Slider is at the
end of travel
Proceed to
Slider Doesn’t
Complete Travel Or
Doesn’t Move At All
diagnostic flow
Check the alignment of
the magnet on the slider
to the proximity switch
closest to it
Proximity switch
and magnet are
aligned
Proximity switch
and magnet are
not aligned
Align
proximity
switch and
magnet
Disconnect the
proximity switch via
the inline connector
near the switch
Check for continuity
at the switch when
the slider magnet
is next to the switch
No continuity
Continuity OK
No continuity
Continuity OK
Replace
switch and
slider
magnet
Replace
wire
Replace
relay board
Check for switch
continuity
measured at J4/J5
of relay board