![Ovation Honor 350C Zoom Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/ovation/honor-350c-zoom/honor-350c-zoom_user-manual_1662270007.webp)
7
V1.3
sistor between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last
fixture.
Art-Net Connection
Connect the Ethernet inputs of all fixtures with the Ethernet network.
Switch/Router
PC/Controlle
r
Art-Net
Art-Net
Occupation of the RJ45-connection:
Honor 350C Zoom installs two RJ45 connectors for DMX data transmission. Pin 1 is for data +, Pin 2 for
data -, Pin 7 & 8 for earthing.
1
2
3
4
5
6
7
8
Ground
-
+
NET IN
+
-
Ground
1
2
3
4
5
6
7
8
NET OUT
Power connection
Power Requirements
The Honor 350C Zoom zoom luminaire operates on 100 to 240 volts AC (+/- 10%, auto-ranging). The lu
-
minaire contains an auto-ranging power supply.
Power linking between fixtures:
The fixture with powercon in and out socket. Connect the power out to the power in socket in the next fix
-
ture till all are connected.
Caution:
maximum power linking - 6 units.
Connection with the mains:
Connect the device to the mains with the enclosed power supply cable.
The occupation of the connection cables as below: