background image

Ins. No.

 

T-518-11-E

NONCONTACT PULSE GENERATORS

 

                                        MODEL PG30

/

PG30EP

MODEL  PG30

MODEL  PG30EP

GB type

Where pulses of scaled units or 
unscaled pulses are required

Pulse generator

for totalizer

LW13 type

CB type

PB type

Meter sizes 52 or 53; 
where pulses in scaled 
units are required.

If unscaled pulses 
uncompensated for 
temperature are re-
quired, it is mounted to 
the area encircled ( ○ ) 
of transmission gear 
box GB.

Equipped with regis-
ter Model LW11;where 
pulses of scaled units 
compensated for tem-
perature are required.

Equipped with regis-
ter Model LW42 or 
43;where pulses of 
scaled units com-
pensated for tem-
perature are required.

Pulse generator

for totalizer

 GENERAL

When used in conjunction with an OVAL flowmeter, the Model PG0/

PG0EP noncontact pulse generator provides voltage frequency pulses 

proportional to the flowrate of process fluid. Incorporated in the pulse 

generator are a premolded pulse generating element and a circuit 

which prevents false pulses otherwise generated by minute vibration 

of generator components. As the toothed disk rotates, a succession of 

voltage pulses (quasi rectangular wave) is generated. 
Generated pulses come either pulses in scaled units or unscaled 

pulses, depending on the position of flowmeter at which the generator 

is mounted. Pulses in scaled units can be used in remote totalizing, 

batching, blending systems and the like built around an OVAL flowmeter 

which serves as the sensing terminal. Unscaled pulses are converted 

into an analog signal for use in flow indicator/recorder/controller 

applications. Models PG0S/PG0SEP are compatible in the latter 

applications. 

 For complete details of Models PG0S/PG0SEP,see OVAL Products

    General Specifications GS No T-5-E.

Pulse generators come in the following two designs:

(1)Standard type

……

PG0

()Flameproof type

PG0EP (designed and fabricated according to the "Explosionproof Guide- 

lines" recommended by the Technology Institution of Industrial Safety.)

 Information about Models PG30S and PG30SEP appears in Instruction Manual No. T-523-E.

 PULSE GENERATOR INSTALLATION EXAMPLES

Generated pulses in scaled units

The rotor revolution is guided into gear reduction and instrumental 

error correction stages for the flowmeter to produce pulses of required scaled unit. The obtained pulse 

signal is used primarily for remote totalization. 

Содержание PG30

Страница 1: ...tes a succession of voltage pulses quasi rectangular wave is generated Generated pulses come either pulses in scaled units or unscaled pulses depending on the position of flowmeter at which the generator is mounted Pulses in scaled units can be used in remote totalizing batching blending systems and the like built around an OVAL flowmeter which serves as the sensing terminal Unscaled pulses are conv...

Страница 2: ...d is desired With PG 0EP use the earth ground terminal furnished With PG 0 no ground terminal is provided take off a screw as shown in Fig and earth ground using a terminal lug OPERATING PRINCIPLE 1 Operation can best be understood by referring to Fig 1 Oscillator coil L1 in the HF oscillator continuously generates a 1MHz high frequency wave waveform As a toothed disk located between the coil and ...

Страница 3: ...asurement with voltmeter alone Correct ON OFF ratio C D ranges from 5 5 to 0 0 when 1 to V and 0 0 5 max If a correct waveform like the one shown in Fig is not obtainable replace the noncontact switch unit with a new one according to the procedure outlined in the next section The ON OFF ratio is a value measured under steady state rotation DISASSEMBLY AND INSPECTION The pulse generator should be d...

Страница 4: ...contact switch unit 108 can be separated by taking off two additional screws 1 0 Remove nut 110 and toothed washer 10 holding the noncontact switch unit 108 to mounting bracket 111 and remove the switch unit Install a new switch unit in alignment with locating slot marked Ensure correct wiring connections with due regard to color coded leads white red and black 1 Take off four bolts and remove the...

Страница 5: ...ement parts Sym No Part Name Q ty 118 Mounting bracket Detector 1 11 Brake shoe 1set 1 0 Plate 1 1 Shoe shaft 1 Spring 1 Clip ring 1 Thrust spacer 1 1 Fitting screw Detector mounting bracket M 8 1 Washer Detector mounting bracket M 1 8 Plate fitting screw M 1 Washer Plate fitting screw M 1 0 Holder fitting screw M 1 1 Washer Holder fitting screw M Mounting Bracket Assembly Sym No Part Name Q ty 01 Mou...

Страница 6: ...Terminal box housing lid 1 0 Fitting bolt Terminal box housing lid 08 O ring JIS G 0 1 0 Bolt Terminal box housing M5 1 10 Washer M5 11 Ground terminal screw M 8 1 Washer M 1 Crimp terminal φ 8 1 Terminal block 1 Sym No Part Name Q ty 15 Flameproof enclosure rating nameplate 1 1 Hex bolt for terminal M 18 1 Washer M 18 Washer M 1 Nut M 1 Terminal block fitting screw M 10 Washer M Washer Terminal bo...

Страница 7: ...1 Crimp terminal 11 Holder 1 115 Shaft 1 11 Toothed disk with hub 1 118 Ball bearing CF 10 0ZZ 11 Brake shoe 1set 1 0 Plate 1 1 Shoe shaft 1 Spring 1 Clip ring Replacement parts Sym No Part Name Q ty 1 Thrust spacer 1 1 5 Blind plug PT1 8 hex socket head 1 1 Terminal identification label 1 1 Wiring instruction label 1 1 Toothed disk setscrew M 1 1 0 Fitting screw Detector mounting bracket M 8 1 1 W...

Страница 8: ...ale G PF female Operating temperature range 0 to 80 Standard supplies DC power supplies are available from OVAL You can use one if required GENERAL SPECIFICATIONS Number of gear teeth toothed disk 5 pole Pulse generator unit Type SHW 1001 Color Green Power Source 1 VDC 10 Current drain 0mA max Output signal levels 0 0 5V max 1 to V across 10kΩ resistive load Maximum operating frequency 5kHz at sen...

Страница 9: ...T 518 11 E ...