Checking the tubing or the flexible hose per month and each time the cylinder is
changed.
-
The tubing or the flexible hose must be changed within the prescribed intervals
or within one year.
-
The hose assembly must be replaced prior to the appliance being put into
operation if there is evidence of excessive abrasion or wear, or if the hose is
damaged, and that the replacement hose assembly shall be that specified by
the manufacturer.
-
The heater should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required as necessary. It is
imperative that control compartment, burners and circulating air passageways
of the appliance be kept clean.
-
Shut off and check heater immediately if any of the following conditions exist:
o The smell of gas in conjunction with extreme yellow tipping of the burner
flames.
o Heater does not reach a proper temperature. A temperature less than 5
℃
will cause restricted heat flow and the appliance will not work properly.
o The appliance starts making popping noises during use (a slight popping
noise is normal when the appliance is extinguished).
-
The regulator & hose assembly must be located out of pathways where people
may trip over it or in area where the hose will not be subject to accidental
damage.
-
Any guard or other protective device removed for servicing the heater must be
replaced before operating the heater.
-
Children and adults should be warned of the hazards of high surface
temperatures and should stay away to avoid burns or clothing ignition.
-
Young children and pets should be carefully supervised when they are in the
area of the heater.
-
Clothing or other flammable materials should not be hung from the appliance, or
placed on or near the appliance.
-
Do not place articles on or against this appliance. Certain material or items
when stored under or near this appliance will be subjected to radiant heat and
could be seriously damaged.
-
Do not use or store flammable materials near this appliance.
-
Do not spray aerosols in the vicinity of this appliance while it is in operation.
-
Always maintain at least 0.9m clearance from combustible materials.
-
Always position the appliance on a firm level surface. An amply ventilated area
must have a minimum of 25% of the surface area open. The surface area is the
sum of the walls surface.
Содержание 842-191
Страница 1: ...ASSEMBLY INSTRUCTION MANUAL IMPORTANT RETAIN FOR FUTURE REFERENCE READ CAREFULLY INbza012_UK 842 191 ...
Страница 5: ...EXPLODED VIEW ...
Страница 7: ......
Страница 8: ......
Страница 9: ...firmly in place ...
Страница 10: ......
Страница 11: ......
Страница 18: ......