Operation
Setting Battery Amp-Hours and Return Amps using the FLEXnet
DC Monitor
If a FLEXnet DC Monitor is installed in the configuration, the following parameters will need to be set.
Battery Amp-Hours refers to the total amp-hour capacity of the battery bank (not just amp-hour
rating of the individual batteries within the battery bank).
Return Amps is the low limit to which an absorption current must decrease, while still maintaining
the absorption voltage, before the battery is judged to be full. Use the battery manufacturer’s
specifications or 2% of the battery bank capacity.
IMPORTANT
:
Access the Advanced Menu as
instructed on page 43.
To change Battery Amp-hours:
1.
Press the <
BAT
> Soft Key.
2.
Press the <
INC
> or <
DEC
> Soft
Key to change the parameter.
3.
Press <
ADV
> to return to PG1.
4.
Press <
PG2
> to advance to the
next setup page.
To change Return Amps:
1.
Press the <
CHARGE
> Soft Key.
2.
Press the <
INC
> or <
DEC
> Soft
Key to change the parameter.
3.
Press <
TOP
> to return to PG2.
4.
Press <
PG3
> to advance to the
next setup page.
5.
Press <
Main
> to return to the
Main Screen.
44
900-0095-01-00 Rev A
Figure 31
Setting Battery Amp-hours and Return Amps
Содержание FLEXpower ONE GVFX3524
Страница 1: ...power ONE T M Installation Manual...
Страница 40: ...Installation 38 900 0095 01 00 Rev A...
Страница 50: ...Operation 48 900 0095 01 00 Rev A...
Страница 60: ...Specifications 58 900 0095 01 00 Rev A This page intentionally left blank...
Страница 62: ...Wiring Configurations 60 900 0095 01 00 Rev A This page intentionally left blank...