Ouellet XLERATOR XL-W-ECO-120 Скачать руководство пользователя страница 1

NOTE:  

Upon completing installation and checking for proper operation, it is 

highly

 recommended that a bead of 

silicone sealant

 be placed around 

the outside of the cover at the wall to protect dryer from internal corrosion caused by wash water and cleaning solutions 

PARTS LIST FOR XLERATOR DRYER 

 
REF NO. 

DESCRIPTION 

 

XL 1 

Cover (includes Nameplate) 

XL 2 

Nameplate 

XL 3 

Tamper-proof Bolt 

XL 4 

Tamper-proof Wrench 

XL 5 

Air Outlet (includes gasket) 

XL 6 

Terminal Block (includes screws) 

XL 7 

Control Assembly & Sensor 

XL 8 

Heating Element Assembly 

XL 9 

Motor Assembly  

XL 10 

Wall Plate Assembly 

XL 11 

Cover Mounting Brackets 

XL 12 

Housing Grommet 

XL 13 

Housing Retainers 

XL 15 

Optics Assembly (Sensor) 

XL 16 

Fuse holder (if so equipped) 

XL 17 

Fuse (if so equipped) 

 
NOTE: Model, Serial Number and Voltage of the 
 

dryer MUST BE included when ordering parts. 

 
INSTALLATION INSTRUCTIONS 

FOR 

XLERATOR

®

 

HAND

 DRYER

 

 

FOR PROPER ELECTRICAL CONNECTIONS, CHECK YOUR LOCAL BUILDING CODES. 

YOUR UNIT MUST BE INSTALLED BY A QUALIFIED, LICENSED ELECTRICIAN. 

 

 
 
 
 
 
 
 

 

 

 
 
 
 
 
 

 

 
 

 
1. Remove cover of dryer by unscrewing two tamper-proof bolts from the sides of the cover with the special wrench provided with each unit.   

 

 

 

 

 

2. Attach wall plate at the four corners to smooth wall.   In locations where vandalism is a concern, use the two additional mounting holes shown.  
  Remove control assembly to access right side mounting hole. Attach with the recommended type of fastener (see above). 

 

3. Identify the voltage of your dryer from the rating sticker of the unit.  Then connect to a dedicated branch circuit not exceeding 20 Amp.  Secure 

electrical wiring to terminals as indicated by the schematic affixed to blower housing.  An identified ground connection point is supplied on the base 
plate for your equipment ground wire.  Dryers should be installed per local code requirements. 

 
4.  In multiple installations, before replacing cover, check the Serial Number marked inside the dryer to be sure it matches the Serial Number marked 
  on the label at the bottom of cover.   

PLEASE DO NOT SWITCH COVERS.  Do not forget to leave the special TAMPER PROOF WRENCH with 

  the owner. 

 

 
 

 
 

INSTALLATION NOTE:

  If the dryer will not turn on, stays on or stops working, it may be mounted too close to a counter or object.  Turn off the 

power to dryer for 10 seconds and then reapply power.  If dryer will start, then turn off again, relocate the object or remount dryer.  If this is not 
possible, adjust the range of the sensor by turning the range adjustment on the control board, counterclockwise to decrease sensor range. 

 

Suggested Mtg. Heights from floor 

 to bottom of dryer 

 

   

Men’s 

45“ (1143 mm) 

Ladies’ 

43“ (1092 mm) 

Teenagers’ 

41“ (1041 mm) 

Sm. Children 

35“ (889 mm) 

Handicapped 

37“ (940 mm) 

 

IF MOUNTING OVER COUNTERTOP, DISTANCE FROM 
COUNTER TO DRYER

 MUST BE 15” (381mm) MINIMUM

 

 

Recommended Fastener 

 

Masonry Wall 

½” expansion sleeve with ¼” lag bolt 

Hollow Wall 

¼” wing type through bolt 

Wooden Wall 

¼” lag screw with washer

 

Отзывы: