6.3 Donning the Prosthesis

Your  Ottobock  team  instructed  you  in  how  to  don  the  prosthesis.  The  following  donning  tech­
nique is well proven:
1)  Apply  the  donning  assist  (e.g.  elastic  bandage/elastic  sock/EasyProth  donning  assist)  over

your residual limb up to the crotch. Include all soft tissue.

2)  Push the free end of the donning assist to the outside through the valve opening.
3)  Slide your residual limb into the prosthetic socket.
4)  Draw the donning assist to the outside. Slide your residual limb into the prosthetic socket.
5)  Gradually  draw  out  the  donning  assist.  Ensure  that  all  soft  tissue  remains  in  the  prosthetic

socket.

6)  Insert the valve and allow the air to escape.
Remove the prosthesis if it does not fit properly. Try donning the prosthesis again. Contact your
prosthetist in case of any problems.

6.4 Wearing of the Prosthesis

WARNING

Operation of motor vehicles

Risk of accidents due to restricted body function

Observe the applicable legal and insurance regulations for the operation of motor vehicles
and have your driving ability examined and certified by an authorised agency.

CAUTION

Excessive strain on load-bearing components

Injuries due to breakage of load-bearing components

Sports activities are only permitted after consultation with your doctor or orthotist.

If the product has been exposed to extreme strain (e.g. due to falling), take any necessary
measures  (e.g.  repair,  replacement,  inspection  by  the  manufacturer's  customer  service
etc.).

An energy-saving and natural gait requires a functional prosthesis. Please consult your prosthetist
if you experience any problems despite correct handling.

6.5 Doffing of the Prosthesis

1)  Remove the valve.
2)  Push the prosthesis down by the socket brim.

7 Cleaning and Care

CAUTION

Use of unsuitable cleaning agents or disinfectants

Impairment of functionality and damage due to incorrect cleaning agents or disinfectants

Only clean the product with the approved cleaning agents.

Only disinfect the product with the approved disinfectants.

Observe the instructions for cleaning and care.

Your prosthesis, especially the inner socket, requires regular cleaning.

Prosthesis

Cleaning  with  a  damp  cloth  will  generally  be  sufficient.  Ottobock  recommends  Derma  Clean  to
disinfect  the  prosthesis.  Clean  any  plastic  surfaces  with  water  and  skin-friendly  soap.  Dry  the
cleaned areas thoroughly. Do not place the prosthesis on a radiator or other heat source. Ensure
that no soap residue is left on the prosthesis, since this could cause skin irritation on the residual
limb.

Содержание Lamination Resin Socket

Страница 1: ...Instructions for use Transfemoral Prosthesis with Synthetic Lamination Resin Socket Custom made device ...

Страница 2: ...2 ...

Страница 3: ...Aspects 4 4 Safety 5 5 Explanation of warning symbols 5 1 5 General safety instructions 5 2 5 Handling 6 6 Shoe Selection 6 1 6 Check 6 2 6 Donning the Prosthesis 6 3 7 Wearing of the Prosthesis 6 4 7 Doffing of the Prosthesis 6 5 7 Cleaning and Care 7 7 Maintenance 8 8 Disposal 9 8 Legal information 10 8 Liability 10 1 8 Table of contents 3 ...

Страница 4: ...l combination best suited to you and your specific needs The prosthetic socket has been adapted so that your residual limb muscles establish a correct con nection without constricting you excessively The prosthetic socket is worn directly on the skin without a residual limb sock The valve promotes adhesion and is removed to doff the prosthesis Prosthesis components Different knee joints and prosth...

Страница 5: ...uctuations please consult your doctor or prosthetist 5 Safety 5 1 Explanation of warning symbols CAUTION Warning regarding possible risks of accident or injury NOTICE Warning regarding possible technical damage 5 2 General safety instructions CAUTION Risk of injury and risk of product damage To avoid the risk of pinching do not reach into the joint mechanism Keep the product away from open flames ...

Страница 6: ...mations poor fit or damage the prosthesis should no longer be used CAUTION Volume fluctuations of the affected limb or problems with the fit e g caused by growth Injuries friction pressure sores circulatory disorders and paralytic symptoms caused by prob lems with the fit If the product is fitted during the growing phase it must be adjusted according to changing body dimensions Check the skin dail...

Страница 7: ...e to breakage of load bearing components Sports activities are only permitted after consultation with your doctor or orthotist If the product has been exposed to extreme strain e g due to falling take any necessary measures e g repair replacement inspection by the manufacturer s customer service etc An energy saving and natural gait requires a functional prosthesis Please consult your prosthetist ...

Страница 8: ...y if any changes occur 9 Disposal In some jurisdictions it is not permissible to dispose of the product with unsorted household waste Improper disposal can be harmful to health and the environment Observe the information provided by the responsible authorities in your country regarding return collection and disposal procedures 10 Legal information All legal conditions are subject to the respective...

Страница 9: ...9 ...

Страница 10: ...10 ...

Страница 11: ...11 ...

Страница 12: ...Template Version 2016 11 23 FM480 SB_148x210 Ottobock 647H923 en_INT 07 2105 ...

Отзывы: