CONGRATULATIONS!
You’ve purchased the finest in natural lighting technology with your new OttLite
®
product.
WARNING:
To prevent electric shock, make sure the lamp is not plugged in until all
steps are complete.
NOTE: THIS UNIT IS FULLY ASSEMBLED
1.
Remove lamp from packing, placing lamp body base (A) flat on a steady surface.
2.
Connect power adapter input (H) into connector (J) in the rear-bottom of the lamp.
3.
Plug the power adapter (G) into a standard household 120V AC outlet.
Note: Only
use with the supplied power adapter to avoid damage or fire.
4.
Turn the lamp
ON & OFF
using power switch in touch panel (B) located on top of
base (A).
5.
Touch panel (B) includes multiple “touch” keys that control the lamp’s mode and
brightness within each mode. This lamp provides five levels of brightness. See
Touch
Key Panel Instructions
section for operating instructions.
6.
Control panel (Q) is used to set the lamp’s calendar, alarm setting and display screen
light. See
Calendar and Clock Setting
section for operating instructions.
7.
Wireless charger for Qi-certified devices (F) is located in the center of the base (A).
See
Wireless Charging Instructions
section for details.
8.
To reposition the light, hold base (A) steady and grasp either lamp body (C) or shade
(D) depending on needed adjustment
9.
Refer to
Diagrams 1 and 2
for lamp maximum adjustment range.
NOTE: DO
NOT FORCE the shade or lamp body outside allowable adjustable range as
excessive adjustment may cause damage.
TOUCH KEY PANEL INSTRUCTIONS:
To power lamp and operate LED settings, slightly touch required “key” to achieve
the following:
• Turn lamp “ON/OFF”: touch
key as needed.
• To adjust brightness: touch
or
key as needed.
•
Touch and hold
M
key to change modes. The three modes are;
ClearSun LED, Sanitizing, and Cl Sanitizing. Cl Sanitizing
mode utilizes both the Clearsun LEDs and Sanitizing LEDs simultaneously to
provide continuous cleaning while using the lamp.
NOTE:
The active mode will be indicated by the lights (N and P) next to the icons.
If indicator light (N) is illuminated, ClearSun mode is on. If indicator light (P) is
illuminated, Sanitizing mode is on. If both indicator lights (N and P) are illuminated,
Cl Sanitize mode is on.
CALENDAR AND CLOCK SETTING:
NOTE: Control Panel (Q) to set Calendar and Clock is located on the backside of
lamp body (C).
• To set time, push
key and the “hour” will flicker,
then touch
ˆ
(up) key and
ˇ
(down) key to adjust “hour,” after “hour”
setting, touch
key again to set the “minute,” “year,” “month” and “day.”
• In setting mode, touch
M
to exit function or operation will stop in one minute.
• When not in setting mode, touch
ˆ
(up) key to switch between “12h” and
“24h” display.
ALARM & SNOOZE FUNCTION SETTING:
• To set the alarm time, press
M
button located on control panel (Q) to activate alarm
setting mode. In alarm mode, touch
button to set alarm time sequence: “Hour,”
“Minute,” “Snooze,” “Music”, then exit.
NOTE:
There are 8-music tones to select.
• Touch
ˆ
(up) key and
ˇ
(down) key to adjust alarm time sequence.
• To activate the alarm press
M
button to activate the alarm setting mode and then
press
ˆ
(up) key and
ˇ
(down) key to turn
ON/OFF
alarm and snooze function.
will light up on digital display to indicate alarm is set.
will light up to indicate
snooze is activated.
• When alarm time is reached, alarm will ring for 1-minute, then snooze and ring again.
Touch
key to turn off alarm or touch
ˆ
(up) key or
ˇ
(down) key to activate
snooze.
NOTE:
Snooze defaults to 60-minutes, if loss of power occurs.
TEMPERATURE SWITCH SETTING:
• In normal mode, touch
ˇ
(down) key to switch between
ºF
and
ºC
display.
To adjust display screen brightness, touch
to choose suitable brightness setting.
NOTE:
Display screen defaults to “highest” brightness setting when power initially applied.
CONTROL PANEL (Q) icon legend
(setting) button – to set calendar; in alarm mode, push
key to turn off alarm.
M
(mode) button – push to set alarm and snooze
ˆ
(up) button – In setting mode, push
ˆ
to increase.
ˇ
(down) button – In setting mode, push
ˇ
to decrease.
– Push display key for suitable brightness.
WIRELESS CHARGING INSTRUCTIONS:
Wireless charging requires a Qi-certified device. To determine if your device is
Qi-certified, please visit the Wireless Power Consortium website.
To wirelessly charge a device, perform the following:
• Place the device, which supports Qi wireless charging standard, face up on the middle
of the Qi wireless charging icon (F).
• When the device is centered on the Qi wireless charging icon (F), a solid
RED
light (E) will indicate the device is charging properly.
NOTE:
If
RED
light is blinking,
this indicates the device is not charging and needs to be properly centered.
• Check the charge level on your device periodically to determine when device is fully
charged.
NOTE:
Product DOES NOT provide any indication of when device is fully
charged.
CAUTION!
DEVICE MAY BECOME WARM DURING CHARGING. THIS IS NORMAL
AND PART OF THE PROCESS. CHARGING TIMES VARY BY DEVICE
SAFETY WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS
1.
Turn lamp off and
WAIT UNTIL LAMP HEAD (D) AND ADAPTER (G) ARE COOL
before handling.
2.
The LED panel (L) located in shade (D) might get hot after several hours of
continuous use
DO NOT
place your hands directly on LED light panel.
3.
Never use with an extension cord unless the plug can be fully inserted into the
receptacles in the extension cord.
4.
Do not alter the plug.
5.
The lamp head included with this unit cannot be replaced by the consumer.
6.
INDOOR USE ONLY
NOTE:
The important safety instructions appearing in this instruction sheet are not meant
to cover all possible conditions and situations that may occur. It must be understood that
common sense, caution, and care must be used with any electrical product.
BATTERY REPLACEMENT
• This lamp uses a CR2032 battery. For battery replacement see diagram 3.
Battery compartment is located on the backside of lamp body (C).
• To remove/install button cell battery: remove battery compartment door
located in the lower half of body section (C) on back-side of lamp. To remove battery
compartment door turn screw counter-clockwise.
• Button cell battery is to be installed with the “+” or flat side facing upward.
• Attach battery compartment door when finished and re-insert screw.
NOTE: DO NOT over-tighten screw to avoid it being stripped.
SAFETY WARNING:
•
CAUTION: DO NOT INGEST BATTERY; CHEMICAL BURN HAZARD!
• This lamp contains a coin/button cell battery. If the coin/button cell battery is
swallowed, it can cause severe internal burns in just two hours and can lead to death.
• Keep new and used batteries away from children.
• If the battery compartment does not close securely, stop using the product and
keep it away from children.
• If you think batteries might have been swallowed or placed inside any part of the
body, seek immediate medical attention.
NOTE:
Coin/button cell batteries are small, single cell devices having a diameter greater
than their height.
ENGLISH
LED Sanitizing Lamp with Wireless Charging
LED Sanitizing Lamp with Wireless Charging
SCEQB00Z-CA SCEQBG5Z-CA 1532520
U14SC
INS210641
REV033121
Diagram 1
Diagram 2
Q
Diagram 3
CAUTION!
Battery Safety:
This
product contains a button
battery. If swallowed, it
could cause severe injury
or death in just 2 hours.
Seek medical attention
immediately.
SEE ADDITIONAL
SAFETY WARNING.
L
D
C
N
(ClearSun mode)
P
(Sanitizing mode)
F
E
A
B
K
G
J
H