9.5 Saving/loading an OTT ecoLog 500 (3G) configuration
The "Load from PC" and "Save to PC" functions are designed to archive the
OTT ecoLog 500 (3G) configuration on a PC. For example, you may configure
multiple OTT ecoLog 500 (3G) units using the same configuration. Additionally,
the "Load from PC" and "Save to PC" functions are required when using the "SMS
command" function (refer to online help).
How to save a configuration
From the "File" menu, select the "Save configuration" function (or use the but-
ton)
➝
The operating program saves the configuration under the name and
number of the OTT ecoLog 500 (3G). When changes are made to a configura-
tion that has already been saved, confirm by clicking "Yes" in the window
"Warning. This configuration name already exists! Replace?" (otherwise, save
the configuration under another station number).
How to load a configuration
From the "File" menu, select the "Load configuration" function
(or use the button).
For an already opened configuration, confirm "Ignore changes?" message by
clicking "Yes" (if necessary, save configuration in advance).
In the "Stored OTT ecoLog 500 (3G) configurations" window, select the config-
uration by double-clicking it
➝
The operating program loads the configuration.
9.6 Importing/exporting an OTT ecoLog 500 (3G) configuration
To transfer an OTT ecoLog 500 (3G) configuration e.g. via USB flash drive or e-
mail, the Import/Export functions are available. Similarly, a configuration can be
sent via the Export function as an XML file to the OTT Hydras 3 user software.
During this process, the OTT Hydras 3 user software creates the entire station/sen-
sor configurations in an OTT Hydras 3 operating range.
Available export/import formats
Export ("BIN" file)
Export to a text file
Export for the OTT Hydras 3 user software
Import ("BIN“ file)
The operating program stores all the necessary data of a configuration in a single
"*.BIN", "*.TXT" or "*.XML" file, depending on the export type.
How to export a configuration ("*.BIN" file)
This export type is required to transfer an OTT ecoLog 500 (3G) configuration as
a "
*
.BIN" file. Using the "Import configuration" function, the configuration can be
read back into the operating program.
From the "File" menu, select the "Export configuration" function.
In the "OTT ecoLog 500 (3G) – export configuration" window, edit the file
name, if necessary, select the storage location, and click "Store"
➝
The operat-
ing program saves the configuration in a "*.BIN" file.
Note
The file name of the "*.BIN" file is arbitrary. The operating program suggests a
combination of station number and station name.