11.2.1
Data Source
This setting determines whether the station will transmit measured sensor data (traditional setup) or files
(created by Python scripts and saved to a specific folder on the SD card). Options are
Measurement
File
This setting should only be changed to File in order to transmit files created by Python scripts on the SD
card.
Please leave this setting at the default Measurement in order to transmit sensor data.
If Data Source is set to File, FTP is the only available Tx Mode. Please see section
for more info.
Max Files Per Tx
Relevant only when Data Source is set to File. Please see section
This setting may be used to limit the number of files transmitted with each transmission.
File Expiry Period
Relevant only when Data Source is set to File. Please see section
This setting is used to ensure that the system does not transmit outdated files. At transmission time, the
time the file was created is checked. It the file was created more than File Expiry Period ago, the file is
deleted.
The File Expiry Period setting is expressed in minutes.
11.2.2
Tx Mode and Protocol
When the station has access to the internet, it may be setup to deliver sensor data to a server. Several
different modes of connecting to a server are provided:
TCPIP
This method uses raw socket communications. The station connects to a port on the server
and delivers the sensor data.
If
Protocol
is set to
HydrometCloud
, there is a bit of handshaking between the station and the
server (see
). This option should be selected when
transmitting to Hydromet Cloud.
If
Protocol
is set to
None
, the raw sensor data is delivered to the server. Use this option if
you are hosting your own server.
for details on the connection.
TCPIP
mode used to be called
Internet Only
prior to version 8.21.
FTP
File transfer protocol is a standard means of transferring files. When this option is chosen,
the station will connect to an FTP server and deliver sensor data as a file.