bATTERIES AND CHARGING

The DRS-100 Diver Recall System is equipped with rechargeable, maintenance-free 

batteries (two 12-volt batteries wired in series) and comes with an RCS-30 smart 

charger.  It is not necessary to remove the batteries to recharge the system.

Note: The battery you receive may have upgraded specifications from what is stated 

in this manual.  Due to advancing battery technologies, we continually upgrade 

our batteries and chargers.  Contact OTS (p. 13) or your local OTS dealer to find 

out the latest available battery and charger.

The DRS-100 can be powered by an external 24-VDC, 7-amp power source (the 

EXT-24 external power supply, sold separately, is available to convert 115 VAC to 

24 VDC) or by its internal rechargeable gel-cell batteries.  If an external 24-VDC 

power supply is used, the internal batteries will partially recharge.  The charging 

source must provide at least 28 volts, 500 mA for batteries to come to a fully 

charged condition.

When the low-battery LED (Fig. 1, #2) begins to flash red, the battery voltage has 

decreased to 20 volts.  Although the DRS-100 can operate with as little as 12 volts, 

we recommend that you recharge the batteries (Section 3.1) as soon as possible 

after the LED starts to illuminate.  If the batteries no longer hold a charge, replace 

them (Section 3.2).

3.1 

bATTERY CHARGING PROCEDURE

WARNINg:

 To avoid damage or injury, read and follow all the instructions below 

before attempting to recharge the batteries.

If you are going to operate the DRS-100 outside the USA, you will need to purchase 

the appropriate power cord for the region of operation.  Power cords are available 

for: Australia (606014-003), UK (606014-002), and Europe (606014-001).
1.  Open the cover.
2.  Turn the relief valve (Fig. 1, #5) fully counterclockwise to open it.
3.  Locate the 24-volt “EXT PWR/CHG” jack (Fig. 1, #7), and insert the plugs 

(+ red and – black) from the RCS-30 smart charger.

Note: Be certain that black is connected to black and red to red.  If they 

are reversed, no harm will occur to the DRS-100, but the batteries will not 

charge.

4.  Connect the RCS-30 smart charger to any power source providing between 

90 and 260 volts AC, 50 or 60 Hz.

5.  The red LED on top of the battery charger should illuminate to indicate the 

charger is properly connected.  The charger may be disconnected when the 

7

Содержание DRS-100 Mod B

Страница 1: ...Undersea Systems International Inc dba OCEAN TECHNOLOGY SYSTEMS Technology in Depth Diver Recall System DRS 100 Mod B User s ManuaL...

Страница 2: ...zards of diving NOTE This manual and the information contained herein are provided for use as a mainte nance and operation guide No license or rights to manufacture reproduce and or sell either the ma...

Страница 3: ...attery Charging Procedure 7 3 2 Battery Removal Replacement 8 Section 4 Maintenance and Troubleshooting 10 4 1 General 10 4 2 Preventive Maintenance 10 4 2 1 Check Prior to Every Dive 10 4 2 2 Mainten...

Страница 4: ...er transducer The typical range is 500 meters but depends on the biological ambient noise level Divers within range listen using only their ears no electronic equipment is necessary The DRS 100 Diver...

Страница 5: ...oximately 20 volts Battery type Two 12 volt 2 6 amp hour maintenance free re chargeable cells in series Battery life 5 hours at 20 duty cycle Recall Tone mode 3 hours nominal when using auxiliary inpu...

Страница 6: ...ll illuminate when power is on 4 TONE RECALL This LED illuminates red when the continuous tone is utilized and green when the intermittent tone is activated 5 Panel ReliefValve Open this valve when ch...

Страница 7: ...nel speaker is used to listen to any un derwater sounds within range e g biological or from human activity The hydrophone volume control 8 adjusts the listening volume 13 Handle You will find two hand...

Страница 8: ...ducer receptacle on the panel and rotate the ring until a good connection is obtained 7 Strain relieve the transducer cable by securing a rope to the strain relief clip on the transducer Additionally...

Страница 9: ...olume rotate the transmit volume control Fig 1 17 clockwise Release the PTT button when you have finished transmitting 2 2 2 3 External Audio To transmit audio from an external source connect an RCA p...

Страница 10: ...reased to 20 volts Although the DRS 100 can operate with as little as 12 volts we recommend that you recharge the batteries Section 3 1 as soon as possible after the LED starts to illuminate If the ba...

Страница 11: ...front panel 8 After a resting period of at least 15 minutes rotate the panel s relief valve clockwise to its closed position Note The RCS 30 smart charger cannot be used as an external power supply It...

Страница 12: ...13 Reconnect J8 J10 J11 J12 and J13 to the circuit board assembly J10 J11 J12 and J13 are labeled and should be connected to the corresponding plugs on the circuit board P10 P11 etc J8 is probably not...

Страница 13: ...nce and troubleshooting Alist of recommended spare parts appears in the Appendix at the end of the manual For service personnel or technically inclined users documentation for more advanced troublesho...

Страница 14: ...are experiencing is not mentioned in the table or if you have tried the suggested solutions and the problem persists contact Ocean Technology Systems see contact information on p 13 for technical sup...

Страница 15: ...ARTS LL 98 transducer with strain relief eyelet p n 900189 000 HSM 10 deluxe noise cancelling hand held microphone p n 910041 000 Line in adapter cable p n 914024 000 optional RCS 30 smart charger wit...

Страница 16: ...reserve the right to decline responsibility where repairs have been made or attempted by other than an Ocean Technology Systems factory trained service center or properly trained personnel In no even...

Отзывы: